![VAT 653 AQ Series Скачать руководство пользователя страница 89](http://html1.mh-extra.com/html/vat/653-aq-series/653-aq-series_installation-operating-and-maintenance-instructions_855917089.webp)
Series 65
MAINTENANCE
982156EB
Edition 2019-06-05
89/110
Description
Required tool
Do not directly expose seals (actuator
and retaining pin feedthroughs) to air
stream!
15. Clean or replace gate seal if necessary.
Install gate o-ring to sealing ring without
grease.
body seal
16. Clean or replace body seal if
necessary.
Lubricate body with the quantity of
vacuum grease listed in the table to
the right.
Valve size
Quantity of grease [ml]
Soft tool
(o-ring remover)
Vacuum grease
DN 100
0.1
DN 160
0.15
DN 200
0.2
DN 250
0.2
17. Install body seal into sealing ring.
18. Deposit vacuum grease on the bottom
side of the body seal according to
drawing below. Pay attention that the
quantity of vacuum grease listed in the
table to the right is distributed
constantly over the whole
circumference.
Valve size
Quantity of grease [ml]
Vacuum grease
DN 100
0.2
DN 160
0.25
DN 200
0.3
DN 250
0.4
Vacuum grease
19. Reassembly the valve in reverse
order, step 9…3.
20. Close the valve bonnet, see steps
31…33.
21. Mount valve bonnet.
•
Tightening torques for bonnet screws,
see in table to the right.
Max. torque 6 Nm
Allen wrench
5mm
22. To leave the maintenance mode press
“Restart” button or power cycle the
controller.
23. Set the valve to remote mode
CPA & Service
cable
(PC to valve
Service
connector)
Apply grease deposit
on this side
Содержание 653 AQ Series
Страница 21: ...Series 65 INSTALLATION 982156EB Edition 2019 06 05 21 110 Controller...
Страница 56: ...INSTALLATION Series 65 56 110 Edition 2019 06 05 982156EB Example...
Страница 109: ...Series 65 APPENDIX 982156EB Edition 2019 06 05 109 110 13 Appendix No information entered on time...
Страница 110: ...Series 65 110 110 Edition 2019 06 05 982156EB This page left blank intentionally...