![VAT 653 AQ Series Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/vat/653-aq-series/653-aq-series_installation-operating-and-maintenance-instructions_855917007.webp)
Series 65
DESCRIPTION OF PRODUCT
982156EB
Edition 2019-06-05
7/110
1.6
Technical data
1.6.1
Control and actuating unit
Description
Power input
1)
(
α
)
+24 VDC (±10%) @ 0.5 V pk-pk max.
connector: POWER
[653 . . - . . A . - . . . . / 653 . . - . . H . - . . . . ]
[653 . . - . . C . - . . . . / 653 . . - . . H . - . . . . ]
70 W max. (operation of valve with max. load) without PFO
3)
with optional SPS + 40 W
with optional PFO + 10 W
3)
Sensor power supply
2)
(
β
)
[653 . . - . . A . - . . . . / 653 . . - . . C . - . . . . ]
input
output
+24 VDC / 1500 mA max.
±15 VDC (±5%) / 1200 mA max.
connector: POWER
connector: SENSOR
Sensor power supply
2)
(
β
)
[653 . . - . . G . - . . . . / 653 . . - . . H . - . . . . ]
input
output
+ 24 VDC resp. ± 15 VDC
same as input but:
2.0 A max. at ± 15 VDC
1.5 A max. at + 24 VDC
connector: POWER
connector: SENSOR
Actuator type
Stepper motor with servo control
Ingress Protection
IP30
1)
Internal overcurrent protection by a PTC device.
2)
Refer to chapter «Sensor supply concepts» for details.
3)
PFO = Power Failure Option. Refer to «Behavior in case of power failure» for details.
Calculation of complete power consumption:
P
tot
=
α
+
β
whereas
β
depends on sensor supply concept and sensor power consumption.
Содержание 653 AQ Series
Страница 21: ...Series 65 INSTALLATION 982156EB Edition 2019 06 05 21 110 Controller...
Страница 56: ...INSTALLATION Series 65 56 110 Edition 2019 06 05 982156EB Example...
Страница 109: ...Series 65 APPENDIX 982156EB Edition 2019 06 05 109 110 13 Appendix No information entered on time...
Страница 110: ...Series 65 110 110 Edition 2019 06 05 982156EB This page left blank intentionally...