Installation, Operating & Maintenance Instructions
Series 650 DN 350 (I.D. 14”), CC-Link
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
286241EA
2010-10-11
37/86
3.6.1.2
Address setting via Terminal function
Command:
0 1 2 3 4 5 6 7 8 9 10
11
12
13
s : 1 0 a b c d 0 0 0 0 CR
LF
code
description
data range
s:10 Command
header
none
a
Cluster address high byte in hexadecimal code
0…F
b
Cluster address low byte in hexadecimal code
0…F
c
Number of valves high byte in hexadecimal code (Master only)
0…F
d
Number of valves low byte in hexadecimal code (Master only)
0…F
•
Command
examples:
for Master valve
Command: s:1000120000<CR><LF>
Answer:
x:10aaaaaabbbbbbbbccccccccddddefghhiiiikl<CR><LF>
Description:
Address allocation to Master valve (cluster address #0) and definition of number of valves
(Master valve included!). In this case the valve cluster consists of 18 valves (12
hex
).