Installation, Operating & Maintenance Instructions
Series 650 DN 350 (I.D. 14”), CC-Link
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
286241EA
2010-10-11
66/86
GENERAL WARNING bitmap table:
Bit
Description
0
SERVICE REQUEST
Valve movement tight
1
LEARN DATA SET
Learn data not present. Learn required for adaptive pressure control.
2
COMPRESSED AIR
compressed air pressure < 4
bar (only for valves with compressed air)
3
POWER FAILURE
BATTERY
Not ready, voltage too low
4
SENSOR OVERLAPPING Sensor deviation between sensor 1 and sensor 2 >= ±10%
5
NOT USED (reserved)
-
6
CLUSTER SLAVE
VALVES OFFLINE
One or more cluster slaves are offline
7-9
NOT USED (reserved)
-
10
SENSOR
MEASUREMENT UNIT
FAULTY
AD-converter of Sensor input 1 and/or 2 (optional, only in case of 2 sensor version) on the
master board is faulty.
11-15
NOT USED (reserved)
-