![VAT 642 GP Series Скачать руководство пользователя страница 77](http://html1.mh-extra.com/html/vat/642-gp-series/642-gp-series_installation-operating-and-maintenance-instructions_4090982077.webp)
Series 642
OPERATION
605593EC
Edition 2017-11-24
77/113
5.2
Close valve
Local operation:
(‘Control View’, ‘Control Performance Analyzer’ or
‘Service Box 2‘)
Remote operation:
(Refer to chapter «Explicit messaging control
commands» for details)
Push CLOSE button
1. Send EXECUTING
(if not yet selected)
2. Send SETPOINT TYPE
= position control
3. Send CONTROL MODE for position
= close valve
5.3
Open valve
Local operation:
(‘Control View’, ‘Control Performance Analyzer’ or
‘Service Box 2‘)
Remote operation:
(Refer to chapter «Explicit messaging control
commands» for details)
Push OPEN button
1. Send EXECUTING
(if not yet selected)
2. Send SETPOINT TYPE
= position control
3. Send CONTROL MODE for position
= open valve
5.4
Position control
The valve position is directly controlled according to the position setpoint.
Local operation:
(‘Control View’, ‘Control Performance Analyzer’ or
‘Service Box 2‘)
Remote operation:
(Refer to chapter «Explicit messaging control
commands» for details)
Select or enter position setpoint
1. Send EXECUTING
(if not yet selected)
2. Send SETPOINT TYPE
= position control
3. Send CONTROL MODE for position
= control mode
4. Send CONTROL SETPOINT = position
Содержание 642 GP Series
Страница 109: ...Series 642 SPARE PARTS 605593EC Edition 2017 11 24 109 113 12 1 Drawing Sample picture All Item refer to chapter Drawing...
Страница 112: ...APPENDIX Series 642 112 113 Edition 2017 11 24 605593EC 13 Appendix No information entered on time...
Страница 113: ...Series 642 605593EC Edition 2017 11 24 113 113 This page left blank intentionally...