4.6.6
ZERO
ZERO allows for the compensation of the sensor offset voltage.
When ZERO is performed the current value at the sensor input is equated to pressure zero. In case of a 2
sensor system both sensor inputs will be adjusted. A max. offset voltage of +/- 1.4 V can be
compensated. The offset value can be read via local and remote operation.
Local operation:
(‘Control Performance Analyzer’ or ‘Service Box 2‘)
Remote operation:
(Refer to chapter «Explicit messaging control
commands» resp. «Explicit messaging setup
commands» for details)
With CPA:
•
Do the ZERO in menu ‘Sensor / Zero’.
With SB2:
•
Go to menu ‘Zero / ZERO’ and follow
instructions.
1. Send EXECUTING
(if not yet selected)
2. Select SETPOINT TYPE
= position control
3. Select CONTROL MODE for position
= open valve
4. Wait until process chamber is evacuated
and sensor signal is not shifting anymore.
5. Send ZERO
•
Do not perform ZERO as long as pressure gauge voltage is shifting otherwise
incorrect pressure reading is the result. Refer to manual of sensor manufacturer for
warm up time.
•
Do not perform ZERO, if the base pressure of your vacuum system is higher than
1‰ of sensor full scale. We recommend disabling ZERO function in this case; refer
to «Valve and sensor configuration» of the setup procedure. Otherwise incorrect
pressure reading is the result.