GAIN FACTOR
The GAIN FACOTR is a control parameter to adapt the performance of the pressure control algorithm. A higher gain
results in faster response, higher over- / undershoot of pressure. A lower gain results in slower response, lower over- /
undershoot of pressure.
Example:
Set SENSOR DELAY of the adaptive pressure controller to the value 0.75
Command
Pressure
controller
Parameter selection variable
Parameter value (seconds)
s:02
A (a)
00 (bb)
0.75 (c)
s:02A000.75
To optimize adaptive control algorithm, refer to chapter «Tuning of control performance».