![VAT 642 GP Series Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/vat/642-gp-series/642-gp-series_installation-operating-and-maintenance-instructions_4090982026.webp)
INSTALLATION
Series 642
26/113
Edition 2017-11-24
605593EC
4.5.4
Power (+24 VDC) and sensor connection (
±
15 VDC sensors) with SPS module
[642 . . - . . A . - . . . . / 642 . . - . . C . - . . . . versions only]
•
VAT fuse recommendation: (a) 5AF, / (b) Safety switch 3A min.
•
Use shielded sensor cable(s). Keep cable as short as possible, but locate it away
from noise sources.
•
Connect Power supply (+24 / GND) at power 5 pol. male connector and Sensors
(0V / + / - / ±15 VDC) at DB–15 female sensor connector exactly as shown in the
drawing above!
Pins 2 and 3 must be
bridged for operation.
An optional switch
would allow for motor
interlock to prevent
valve from moving.