Series 642
OPERATION
605593EC
Edition 2017-11-24
75/113
5.1.1
Local operation
Local operation means that the valve is operated via the service port using a computer or the Service Box
2. When using a computer, a service cable and a software from VAT is required.
You can use our Software (freeware) 'Control Performance Analyzer' which can be downloaded from:
http://www.vatvalve.com/customer-service/informations-and-downloads/control-performance-analyzer.
These softwares are beneficial especially for setup, testing and maintenance.
How to start:
Connect service cable between PC and valve controller, start software and push button ‘LOCAL’ to
enable for operation. Then enter menu Sensor / Setup and do sensor configuration according to your
application to make sure that you get the correct pressure displayed.
‘
'Control Performance
Analyzer' supports:
-
Valve setup
-
Sensor setup
-
Pressure control
-
Interface setup
-
Manual control
-
Sequence ontrol
-
Numeric and
graphical
monitoring
-
Data recording
-
Data analysis
-
Advanced
diagnostic
When communication to service port is interrupted the valve will change to remote
operation. So when service cable will be disconnected or software will be shut down,
the valve returns automatically to remote operation. This may result in an immediate
movement of the valve depending on remote control.
Refer to «Accessories» for ordering numbers of service cable and Service Box 2.