INSTALLATION
Series 642
62/113
Edition 2017-11-24
605593EC
Command
(DeviceNet
®
term
if deviant)
Service Code
Class ID
Instance ID
Attribute ID
Service
data length
(number of bytes)
Service
data field
Description
POSITION
SETPOINT
Set
16
51
2
6
2 or 4
Y
Get
14
51
2
6
2 or 4
Y:
position setpoint according to selected DATA TYPE, 0 (closed) … 10’000 (open)
This command transfers/reads the position setpoint to/from the valve.
PRESSURE
SETPOINT
Set
16
51
1
6
2 or 4
Y
Get
14
51
1
6
2 or 4
Y:
pressure setpoint according to selected DATA TYPE,
nominal pressure range is 0 … 10’000 (sensor full scale) but it may be scaled,
refer also to command GAIN for details.
This command transfers/reads the pressure setpoint to/from the valve.
ASSEMBLY
OBJECTS
Set
16
4
7
8
102
3
X
Y
Get
14
4
3
4
5
13
14
100
101
3
X
X, Y:
depending on respective assembly object, refer to «Assembly objects» for details.
Instance ID = assembly object number.
This command writes/reads the respective assembly object.
Unless otherwise specified all values in the table above are in decimal notification. Hexadecimal values
are indicated by the letter ‘h‘ (e.g. 31h)