10
Värmebaronen EP- 900, -1080, -1200, -1400
Operating menu, Adjustment menu
Operating menu
SINGLE Tout +XX°C
CP� VENT�
ACTUAL TEMP XX°C
OUTPUT XXX.XkW
ĮTEMP.SET VALUE 70°C
--------------------
- MENU SELECTOR
SINGEL
“SINGLE”, information, changes with series operation, option.
CP� VENT�
CP�
pump in operation.
CP
flashing, pump paused.
See 'CP function' in the installation menu.
VENT�
cooling fan in operation.
VENT
cooling fan paused.
ACTUAL TEMP. XX°C
Information, current boiler temperature.
OUTPUT XXX.XkW
Information, current connected power.
ĮTEMP.SET VALUE 70°C
Setting, desired boiler temperature, 20 - 95°C, setpoint. The
setting range is affected by max. and min. limits.
The arrow at the beginning of the line does not appear if
the boiler is equipped with a OTC function. In this case, the
temperature is set in the Adjustment menu - with outdoor
temperature compensation, OTC.
Adjustment menu
ĮMAX SET LIMIT 95°C
MIN SET LIMIT 20°C
--------------------
RESET PEAK VAL. [OK]
--------------------
SHUT DOWN BOILER N
- MENU SELECTOR
ĮMAX SET LIMIT 95°C
ĮMIN SET LIMIT 20°C
Max. and min. limits of the range for setting the boiler's
temperature setpoint.
MAX SET LIMIT
55 - 105°C.
MIN SET LIMIT
20 - 50°C.
ĮRESET PEAK VAL. [OK]
Resetting all the high values in the information menu.
ĮSHUT DOWN BOILER N
Set boiler in standby position (switched off).