VÄRMEBARONEN EP 31 300
Operating menu, Adjustment menu
Operating menu
SINGLE Tute +XX°C
CP� VENT�
BOILER TEMP. XX°C
PWR. OUTPUT XXX.XkW
ĮTEMP. SETPOINT 70°C
-to MENU SELECTOR!
SINGEL
“SINGLE”, information, changes with series operation, option.
CP� VENT�
CP
�
: pump in operation.
CP
: flashing, pump paused.
See 'CP function' in the installation menu.
VENT
�
: cooling fan in operation.
VENT : cooling fan paused.
BOILER TEMP. XX°C
Information, current boiler temperature
PWR. OUTPUT XXX.XkW
Information, current connected power.
ĮTEMP. SETPOINT 70°C
Setting, desired boiler temperature, 20-95°C, setpoint.
The setting range is affected by max. and min. limits.
Adjustment menu
ĮMAX TEMP SET 95°C
MIN TEMP SET 20°C
--------------------
RESET PEAK VALUE(OK)
--------------------
BOILER IN STANDBY? N
-to MENU SELECTOR!
ĮMAX TEMP SET 95°C
ĮMIN TEMP SET 20°C
Max. and min. limits of the range for setting the boiler's
temperature setpoint.
Max. limit: 55-105°C.
Min. limit: 20-50°C.
ĮRESET PEAK VALUE(OK)
Resetting all the high values in the information menu.
ĮBOILER IN STANDBY? N
Set boiler in standby position (switched off).