Varec, Inc.
13
Chapter 3
Mounting
The 2920 FTT can be mounted in the following ways:
• Mount the complete transmitter on a 2500 ATG gaugehead (see “Mounting on a
• Mount the complete transmitter on a non-Varec gauge (see “Mounting on Alternate
• Mount standalone on a 2" pipe for gauging applications where the 2920 FTT
functions as a tank side integrator for HART level instrumentation (i.e., radar) as well
as spot temperature or HART average temperature.
This chapter describes each of the above procedures.
The tank can remain in-service and the mechanical float gauge can remain in place while
installing and configuring the 2920 FTT.
Note
Please read the safety guidelines section before beginning the mounting process.
Installation Safety Guidelines
• This equipment should be installed only by qualified personnel familiar with the
installation of tank gauging equipment.
• Caution should be exercised when entering any area that is posted or otherwise
assumed to contain hazardous gases. Always follow other local guidelines.
• Obtain a hot permit before removing the transmitter cover with power applied.
• To prevent shock hazards, the housing of all units should be properly grounded in
accordance with the National Electric Code. A grounding conductor should be wired
to the grounding terminal provided on the 2920 FTT.
• Refer to Chapter 2, Installation: "Correct Sealing of the Junction Box Covers" make
sure the o-ring is properly seated on the base of the cover.
Warning! Before attempting installation of the 2920 FTT, review the General Safety
Guidelines. Installation and maintenance personnel should become familiar with any
hazards present as well as any agency requirements before working with any equipment.
Mounting on a Varec Gaugehead
This procedure provides instructions to mount the transmitter on a 2500 ATG gaugehead.
Instructions applicable to other tank gauges follow in later paragraphs. To install the
gaugehead, refer to the
2500 Automatic Tank Gauge Installation and Operations Manual
. The
exploded view in that manual shows the mechanical relationship between this accessory and
the gaugehead.
Содержание 2920
Страница 2: ......
Страница 16: ...2920 Float Tape Transmitter 1 Introduction 6 Installation and Operations Manual...
Страница 114: ...2920 Float Tape Transmitter 6 Bi Phase Mark 104 Installation and Operations Manual...
Страница 120: ...2920 Float Tape Transmitter 7 MODBUS 110 Installation and Operations Manual...
Страница 126: ...2920 Float Tape Transmitter 9 L J TankWay 116 Installation and Operations Manual...
Страница 138: ...2920 Float Tape Transmitter 11 Configuration Calibration Level Limits and Outputs 128 Installation and Operations Manual...
Страница 148: ...2920 Float Tape Transmitter 12 Maintenance and Troubleshooting 138 Installation and Operations Manual...
Страница 158: ...2920 Float Tape Transmitter 14 Ordering Information 148 Installation and Operations Manual...
Страница 178: ...2920 Float Tape Transmitter MODBUSAppendix A MODBUS Implementation 168 Installation and Operations Manual...
Страница 193: ......