2920 Float & Tape Transmitter
10 Configuring HART Devices
120
Installation and Operations Manual
secondary display to show product temperature, vapor temperature, and product pressure at
5 second intervals.
To Set the Secondary Display
1. Press Enter to open the Main Menu.
2. Press Enter to open the System Data menu.
3. Press Minus 2 times to the Config Params.
4. Press Enter to open the Config Params menu.
5. Press Minus to the Sec. display 1. If the 2920 FTT has not been changed from the default,
the Sec. display 1 shows TANK Temp.
6. Press Enter to open the Sec. display 1.
7. Press Minus to move through the display options for Sec. display 1.
8. Press Enter to select the appropriate display.
To Set Additional Items to Display
1. Press Enter to open the Main Menu.
2. Press Enter to open the System Data menu.
3. Press Minus 2 times to the Config Params.
4. Press Enter to open the Config Params menu.
5. Press Minus to the Sec. display 1. If the 2920 FTT has not been changed from the default,
the Sec. display 1 shows TANK Temp.
6. Press Enter to open the Sec. display 1.
7. Press Minus to move through the display options for Sec. display 1.
8. Continue steps 5 through 7 for each Sec. display #.
9. In the Config Params menu, press Minus (or Plus) to locate Scroll Rate.
10. Press Enter to open Scroll Rate.
11. Press Plus to increment the Scroll rate one second per press.
12. Press Enter to save the appropriate Scroll rate.
13. Press Cancel to return to the Main menu. When the LCD returns to the default view, the
secondary display changes to the variables selected at the selected interval.
Содержание 2920
Страница 2: ......
Страница 16: ...2920 Float Tape Transmitter 1 Introduction 6 Installation and Operations Manual...
Страница 114: ...2920 Float Tape Transmitter 6 Bi Phase Mark 104 Installation and Operations Manual...
Страница 120: ...2920 Float Tape Transmitter 7 MODBUS 110 Installation and Operations Manual...
Страница 126: ...2920 Float Tape Transmitter 9 L J TankWay 116 Installation and Operations Manual...
Страница 138: ...2920 Float Tape Transmitter 11 Configuration Calibration Level Limits and Outputs 128 Installation and Operations Manual...
Страница 148: ...2920 Float Tape Transmitter 12 Maintenance and Troubleshooting 138 Installation and Operations Manual...
Страница 158: ...2920 Float Tape Transmitter 14 Ordering Information 148 Installation and Operations Manual...
Страница 178: ...2920 Float Tape Transmitter MODBUSAppendix A MODBUS Implementation 168 Installation and Operations Manual...
Страница 193: ......