XII. TROUBLESHOOTING
Common issues will be reported on the Vision GCS display as a warning/error
message. For example, a lost or low link strength will result in a message
displayed on the GCS, indicating that action should be taken.
Below is a list of common issues, how to identify them, and troubleshooting
steps to resolve them.
To change notifications or failsafe settings refer to section: PROGRAM FAILSAFE
TRIGGERS & EMERGENCY PROCEDURE.
PAIRING
74
Problem
Indicator
Response
Cannot get
Vesper into
pairing mode
No tone
indicating
successful
pairing
1.
Disconnect battery, wait a few
seconds, then reconnect.
2.
Repeat pairing instructions (see
page 10).
Gimbal clacks
back and forth
when turning
Vesper upside
down to pair
Gimbal
clacking
Wait a full 60 seconds from startup
before flipping upside down.
Pairing process
gets stuck on
“Searching”
screen
Searching
screen shown
for > 60
seconds
1.
Confirm Vesper is on by checking
the gimbal is active.
2.
Confirm radio connections are
plugged in.
3.
Cancel pairing attempt on QGC
and redo the process to put
Vesper and GCQ into pairing
mode and wait another 60
seconds.
Содержание Vesper UAS
Страница 1: ...Vesper UAS Vision GCS Operator s Manual v1 8...
Страница 4: ...I SYSTEM COMPONENTS CONTROLS VESPER VISION GROUND CONTROL SYSTEM VISION GCS 4...
Страница 12: ...12...
Страница 39: ...3 Click the PAIRING icon in the upper right of QGC 4 A Discovering indicator will appear 39...
Страница 56: ...Accessing Ubuntu System Settings 1 Tap the menu bar in the top right to access the quick settings menu 56...
Страница 59: ...6 Enter the default password Vantage1 and then enter a new password Tap Change to complete the change 59...