Vanderbilt
17
A6V10200077_e
Installation Instructions
08.02.2016
6.2
Indicator module
6.2.1 Figure 6: Indicator module
A
LED lights up
red constantly
Alarm
B
LED flashes red
First alarm
C
LED off
No alarm
D
Key switch DET
test
Check all seismic de-
tectors that are con-
nected to this display
module
E
Key switch LED
test
Check LED in indicator
module
F
Inscription box
6.2.2 Switching the indicator module
The indicator module is automatically activated via the key module in the
Display ON
key position (Fig.5, item,
F). Saved alarms are displayed. The function of the LED and the connected seismic detectors can also be tested
individually for each indicator module. To do this, press and hold down the corresponding key switch. Once re-
leased, the normal display is active.
DET test:
This test is only possible if the intruder alarm system is disarmed.
Press and hold
down key switch
Connected seismic detectors are tested
LED flash slowly
After 3 seconds
Alarm memory is cleared
LEDs flash quickly
After 5 seconds
New test is carried out
LED test:
This test is only possible if the intruder alarm system is armed.
Press and hold
down key switch
All LEDs in this indicator module are tested.
LED lights up constantly if the LED is functioning cor-
rectly.
7
Maintenance
The product is maintenance-free. Damage should be rectified immediately.
In terms of disposal, the device is considered a used electronic device subject to European Directive
2002/96/EC (WEEE) and must not be disposed of with domestic waste. The device should be dis-
posed of via the intended channels. Local legislation and that valid at the time must be taken into ac-
count.