Vanderbilt.
21
A6V10200077_e
Installationsanweisungen
08.02.2016
Cause
System
Status
GMA7-S Key
Position
GMA7-S LED
(colour)
GMA7-A LEDs 1-8
Notes
5.2
Set
Display On
On
First detector pulsing,
next detector(s) con-
stant
Ok
5.3
Unset
Display On
On
First detector pulsing,
next detector(s) con-
stant
5.4
Set
Display on
on
Off
Clear alerts from
panel & set, LED's
now off
6
First detector
activates
Set
Display On
On
Pulsing LED for first
activated detector
Ok
6.1
Second detec-
tor activates
Set
Display On
On
Constand LED for next
detector(s) activated
Ok
6.2
Unset
Display On
On
First detector pulsing,
next detector(s) con-
stant
Ok
6.3
Set
Display On
On
First detector pulsing,
next detector(s) con-
stant
Clear alerts from
panel, clears stored
alarms from
memory
6.4
Unset
Display On
On
Off
Setting system
clears all stored
alarms