Details for ordering
V54534-F101-A100
Remote testing system for seismic detectors (type: GMYA7-AS)
V54534-F102-A100
Alarm for indicator module (type: GMYA7-A)
VA5Q00006246
SensTool Software
V54534-F109-A100
GM775 Seismic detector
VBPZ:4202370001
GMXS1 Internal Test transmitter
12
Cause and effect
Cause
System
Status
GMA7-S Key
Position
GMA7-S LED
(colour)
GMA7-A LEDs 1-8
Notes
1
Set
Off
Off
Off
No function
1.1
Set
Display On
On
Off
No function
2
GMA7-A LED
Test
Set
Display On
On
All LED's on.
On for duration of
test
2.1
GMA7-A Det
Test
Set
Display On
On
Off
No function
2.2
Set
System Test
On
Off
No function
2.3
GMA7-A LED
Test
Set
System Test
On
Off
No function
2.4
GMA7-A Det
Test
Set
Display On
On
Off
No function
3
Unset
Display off
Off
Off
No function
3.1
Unset
Display On
On
Off
No function
3.2
GMA7-A LED
Test
Unset
Display On
On
Constant
On for duration of
test
3.3
GMA7-A Det
Test
Unset
Display On
On
4 slow pulse, 4 fast
pulses, then LED's for
devices tested remain
constant until test but-
ton is released.
Hold test button un-
til confirmation of
activation from de-
tector(s)
4
Unset
System Test
Pulses for du-
ration of test
and then con-
stant
4 slow pulse, 4 fast
pulses, then LED's for
devices tested remain
constant until key
switch is moved from
system test.
Ok
5
First detector
activates
Set
Off
Off
Off
Ok
5.1
Second detec-
tor activates
Set
Off
Off
Off
Ok