SECTION 7: TROUBLESHOOTING
AIR IN ARC
®
200 SERIES ALL-IN-ONE POWER SYSTEM
®
PAGE - 108
090019-OP_r0
COMPRESSOR (CONTINUED)
System operating pressure below
specified minimum (continued)
Pressure control out of adjustment or
malfunctioning
Pressure settings may need to be reset.
Consult
Section 6.5.5, Adjusting the Cut-
in / Cut-out Pressure
.
System operating pressure below
specified minimum (continued)
System leaks or is damaged
Inspect for leaks. Repair and/or replace
damaged parts as necessary. Use
Section
9, Illustrated Parts List
to visually confirm/
identify any part that needs to be replaced
before ordering part.
Pressure switch set too low/
malfunction
Adjust pressure switch setting. Refer to
Section 6.5.5, Adjusting the Cut-in / Cut-
out Pressure
. Replace if switch continues
to deviate from setting.
Input rpm too low
Adjust to proper setting.
Clogged compressor air filter
Check air filter. Replace if necessary; refer
to
Section 6.5.1, Compressor Air Filter
.
Incorrect engine speed
Reduce load. Refer to
Section 6.5.6
.
Pilot valve stuck open
Check valve; clean or replace if necessary.
Excess amount of oil in air
discharge
Compressor oil level too high
The correct oil level is the half-way mark on
the sight glass with the compressor shut
down, and the machine on a level surface.
Drain excess oil to correct level. Consult
Section 6.5.2, Compressor Oil
Maintenance
.
Excessive oil consumption
Worn piston ring
Replace; consult Vanair
®
Service
Department for pison ring and cylinder
maintenance procedures.
Worn piston
Replace; consult Vanair Service
Department for pison ring and cylinder
maintenance procedures.
Worn cylinder
Replace; consult Vanair Service
Department for pison ring and cylinder
maintenance procedures.
DC GENERATOR
Welder and/or battery charger
behave erratically
Connection cables or receptacles are
soiled/contaminated
Check for twisted cables and/or soiled/
contaminated or loose receptacle
connections.
Continued on next page
7.3 TROUBLESHOOTING GUIDE
Fault/Malfunction
Possible Cause
Corrective Action
Содержание 050817
Страница 3: ...Addendum 090044 AIR N ARC 250 SERIES ALL IN ONE POWER SYSTEM ADDENDUM PAGE III BLANK PAGE...
Страница 18: ...GLOSSARY AIR N ARC 200 SERIES ALL IN ONE POWER SYSTEM PAGE X 090019 OP_r0 BLANK PAGE...
Страница 22: ...WARRANTY PROCEDURE AIR N ARC 200 SERIES ALL IN ONE POWER SYSTEM PAGE XIV 090019 OP_r0 BLANK PAGE...
Страница 56: ...SECTION 3 SPECIFICATIONS AIR N ARC 200 SERIES ALL IN ONE POWER SYSTEM PAGE 34 090019 OP_r0 BLANK PAGE...
Страница 76: ...SECTION 5 OPERATION AIR N ARC 200 SERIES ALL IN ONE POWER SYSTEM PAGE 54 090019 OP_r0 BLANK PAGE...
Страница 132: ...SECTION 7 TROUBLESHOOTING AIR IN ARC 200 SERIES ALL IN ONE POWER SYSTEM PAGE 110 090019 OP_r0 BLANK PAGE...
Страница 139: ...AIR N ARC 200 SERIES ALL IN ONE POWER SYSTEM SECTION 9 ILLUSTRATED PARTS LIST 090019 OP_r0 PAGE 117 NOTES...
Страница 168: ...SECTION 9 ILLUSTRATED PARTS LIST AIR N ARC 200 SERIES ALL IN ONE POWER SYSTEM PAGE 146 090019 OP_r0 BLANK PAGE...
Страница 178: ...APPENDIX A ADDITIONAL INFORMATION AIR N ARC 200 ALL IN ONE POWER SYSTEM PAGE 156 090019 OP_r0 BLANK PAGE...
Страница 182: ...APPENDIX B MAINTENANCE SERVICE LOG AIR IN ARC 200 ALL IN ONE POWER SYSTEM PAGE 160 090019 OP_r0 BLANK PAGE...
Страница 183: ...BLANK PAGE...