AIR N ARC
®
300 SERIES ALL-IN-ONE POWER SYSTEM
®
SECTION 3: SPECIFICATIONS
090034-OP_r0
PAGE - 33
SECTION 3:
SPECIFICATIONS
TABLE 3A: SPECIFICATIONS - WELDER AND GENERATOR
SYSTEM INFORMATION
SPECIFICATION
Rated Welder Output
300A
High Frequency DC/CC, DC/CV; 100% Duty Cycle @ 280 Amps
Welding Leads
25 or 50 Ft Optional (Refer to
Section A.5
for Optional Parts Listing)
AC Generator
6800 Watts Continuous Duty (Capacitor style)
AC Generator 120V Power Rating
60 Hz 1 PH, 2-20 Amp Circuits
AC Generator 240V Power Rating
60 Hz 1 PH, 28 Amp
Battery Charger Capacity
12V Charge, 12V Boost, 24V Boost
TABLE 3B: SPECIFICATIONS - MOTOR
MOTOR INFORMATION
SPECIFICATION
Motor
17.7 GPH (3000 RPM) (2800 PSI Maximum Working Pressure)
Fluid
Mineral Oil Based Hydraulic Fluids to ISO/DIN
Viscosity
From 60 to 456 SSU [12 to 100mm
2/
5
(cSt)] rec. up to 3410 SSU[750mm
2/
5
(cSt)]
permitted.
Filtration
Contamination class NAS1638:9; ISO 4406:20/18/15. Achieved with filter ß
10 (c)
>
75:10mm
Operating Temperature Limits
0°F to 110°F (-18°C to 43°C); Cold Weather Kit extends temperature range from 0°F to
-40°F (-18°C to -40°C)
TABLE 3C: SPECIFICATIONS — AIR COMPRESSOR
COMPRESSOR INFORMATION
SPECIFICATION
Compressor Type
Single Stage, Oil Injected Rotary Screw
Air Compressor Capacity
40 CFM @ 175 PSI
Inlet Control
Zero (0) No Load / 100% Load
Air Filter
Pleated Paper, Dry Type
Oil Filter
Spin-on Type
Oil Capacity/Type
New:
3 Quarts /
Service:
2 Quarts [Vanguard™ Premium Synthetic Oil]
Air Tank Capacity
Four (4) Gallons
Tank Pressure Rating
200 PSI
Safety Relief Valve Setting
200 PSI
Operating Range (ambient)
0° to 110°F (-18°C to 43°C); Cold Weather Kit needed for operating below 0°F(-18°C)
Electrical System
12 VDC
Cooling System
Air to Oil Heat Exchanger
Instrument Gauges
Pressure and Hour Meter
Adjustable Air Pressure Control
Settings
Cut-in Pressure: 100 PSI / Cut-out Pressure: 125 PSI (Factory Preset); 150/175 PSI
(Maximum Cut-in/Cut-out)
Air Service Outlets
Two (2) on Control Panel, One (1) on Machine
Содержание 050735
Страница 10: ...TABLE OF CONTENTS AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE VIII 090034 OP_r0 BLANK PAGE ...
Страница 14: ...GLOSSARY AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE XII 090034 OP_r0 BLANK PAGE ...
Страница 37: ...AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM SECTION 1 SAFETY 090034 OP_r0 PAGE 19 ...
Страница 54: ...SECTION 3 SPECIFICATIONS AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE 36 090034 OP_r0 BLANK PAGE ...
Страница 69: ...AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM SECTION 4 INSTALLATION 090034 OP_r0 PAGE 51 BLANK PAGE ...
Страница 84: ...SECTION 5 OPERATION AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE 66 090034 OP_r0 BLANK PAGE ...
Страница 126: ...SECTION 7 TROUBLESHOOTING AIR IN ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE 108 090034 OP_r0 BLANK PAGE ...
Страница 130: ...SECTION 8 DIAGRAMS AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE 112 090034 OP_r0 BLANK PAGE ...
Страница 133: ...AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM SECTION 9 ILLUSTRATED PARTS LIST 090034 OP_r0 PAGE 115 NOTES ...
Страница 166: ...SECTION 9 ILLUSTRATED PARTS LIST AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE 148 090034 OP_r0 ...
Страница 174: ...APPENDIX A ADDITIONAL INFORMATION AIR N ARC 300 ALL IN ONE POWER SYSTEM PAGE 156 090034 OP_r0 BLANK PAGE ...
Страница 178: ...APPENDIX B MAINTENANCE AND SERVICE LOG AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE 160 090034 OP_r0 BLANK PAGE ...
Страница 179: ...BLANK PAGE ...