AIR N ARC
®
300 SERIES ALL-IN-ONE POWER SYSTEM
®
SECTION 5: OPERATION
090034-OP_r0
PAGE - 57
while welding.
5.4.1 WELDER OPERATING PROCEDURE
5.4.1.1 CC (CONSTANT CURRENT) MODE
CC (Constant Current) Mode is commonly referred to as -
Stick Welding, Arc Welding, or Shielded Metal Arc
Welding (SMAW)
1. With the motor shut off, insert the twist lock
connections of the ground clamp and the
electrode holder cables into the welder
connection ports on the control panel. For
Direct Current Electrode Positive (DCEP)
connect the electrode holder to the positive
(+) port, and the ground clamp to the
negative (–) port. For Direct Current
Electrode Negative (DCEN) connect the
System Operation Group
Manual
Section
Location
Operating the Welder
5.4
page 56
Welder Operating Procedure
5.4.1
page 57
CC (Constant Current) Mode
5.4.1.1
page 57
CV (Constant Voltage) Mode - Using a
Voltage Sensing Suitcase Feeder
5.4.1.2
page 59
CV (Constant Voltage) Mode - Using a
Spool Gun
5.4.1.3
page 59
NOTE
The amps/volts display will read the set
value for five (5) seconds when the dial is
adjusted, and the actual output value five
(5) seconds after the dial has been
adjusted.
WARNING
Do not rely on the thermal overload
circuit breakers on the generator to
protect personnel, power tools, or the
generator. The thermal overload circuit
breakers on the generator require time to
overheat when the generator is operating
in an overload condition — they do not
provide instant protection against short
circuiting or overload conditions. Always
use GFCI protected extension cords and
power strips when using the generator.
TABLE 5A: MOTOR THROTTLE CONTROL FUNCTION CONDITIONS
I
Compressor Switch
Generator Switch
Welder Switch
Motor Speed Condition Result
ON
OFF
OFF
Motor runs at full speed (3000 RPM).
OFF
OFF
OFF
Motor is bypassed (0 RPM), ready for
application.
ON
OFF
ON
Welder can be activated by striking an arc, and
Motor runs at full speed (3000 RPM), ready for
application.
ON
ON
OFF
Motor runs at full speed (3000 RPM); generator
is ready for use
II
.
ON
ON
ON
Full speed and all items available for use.
I
Any combination of the 300 Power System output functions (compressor, generator, welder) used simultaneously at
capacity will have an adverse affect on operation.
II
Consult
Appendix A, Section A.3, Wattage Requirements for Common Receptacle Units
for a listing of wattage
requirements of various implements.
Содержание 050735
Страница 10: ...TABLE OF CONTENTS AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE VIII 090034 OP_r0 BLANK PAGE ...
Страница 14: ...GLOSSARY AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE XII 090034 OP_r0 BLANK PAGE ...
Страница 37: ...AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM SECTION 1 SAFETY 090034 OP_r0 PAGE 19 ...
Страница 54: ...SECTION 3 SPECIFICATIONS AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE 36 090034 OP_r0 BLANK PAGE ...
Страница 69: ...AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM SECTION 4 INSTALLATION 090034 OP_r0 PAGE 51 BLANK PAGE ...
Страница 84: ...SECTION 5 OPERATION AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE 66 090034 OP_r0 BLANK PAGE ...
Страница 126: ...SECTION 7 TROUBLESHOOTING AIR IN ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE 108 090034 OP_r0 BLANK PAGE ...
Страница 130: ...SECTION 8 DIAGRAMS AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE 112 090034 OP_r0 BLANK PAGE ...
Страница 133: ...AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM SECTION 9 ILLUSTRATED PARTS LIST 090034 OP_r0 PAGE 115 NOTES ...
Страница 166: ...SECTION 9 ILLUSTRATED PARTS LIST AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE 148 090034 OP_r0 ...
Страница 174: ...APPENDIX A ADDITIONAL INFORMATION AIR N ARC 300 ALL IN ONE POWER SYSTEM PAGE 156 090034 OP_r0 BLANK PAGE ...
Страница 178: ...APPENDIX B MAINTENANCE AND SERVICE LOG AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE 160 090034 OP_r0 BLANK PAGE ...
Страница 179: ...BLANK PAGE ...