SECTION 7: TROUBLESHOOTING
AIR IN ARC
®
300 SERIES ALL-IN-ONE POWER SYSTEM
®
PAGE - 106
090034-OP_r0
COMPRESSOR (CONTINUED)
Excess amount of oil in air
discharge
Machine not on level surface
Move machine to level surface.
Compressor oil level too high
The correct oil level is between the bottom
of the oil port threads (low level) to the top
lip of the port’s threads (high level). Drain
excess oil to correct level.
Tank not positioned with the drain at its
lowest point. Reposition machine.
NOTE:
Machine must be operated while on a level
surface in order for proper compressor oil
circulation throughout the system.
Scavenger system not operating
Inspect scavenger line for obstructions or
leaks. Replace if necessary.
Coaleser element plugged or damaged Replace the coalescer element. Consult
Section 6.6.6, Replacing the Spin-on Air/
Oil Coalescer
. Order replacement
coalescer element—see
Table 9A: Recom-
mended Spare Parts List
.
Excessive moisture in the
compressed air
Moisture accumulating in air tank
Drain water from air tank. Refer to
Section
6.6.9, Draining the Air Tank
.
Compressor not running long enough
Run compressor long enough to get hot.
WELDER
Welder and battery charger
behave erratically
Connection cables or receptacles are
soiled/contaminated
Check for twisted cables and/or soiled/
contaminated or loose receptacle
connections.
Untwist and/or straighten out any suspected
cable tensions. Carefully wipe off any
contaminants to receptacle connectors
before re-connecting. Replace any worn or
damaged cables or receptacles. Contact
Vanair
®
Mfg., Inc. Service Department if
behavior persists.
Connections not making contact
Correct connection at lug and clamp
Belt slipping
Re-tension or replace belt. Refer to
Section
6.6.14.3, Re-tensioning the Generator
Serpentine Belt
, and
Section 6.6.14.4,
Replacing the Generator Serpentine Belt.
Welding function is not drawing enough
operating power
If running more than one function
simultaneously, turn off competing function.
Continued on next page
7.2 TROUBLESHOOTING GUIDE
Fault/Malfunction
Possible Cause
Corrective Action
Содержание 050735
Страница 10: ...TABLE OF CONTENTS AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE VIII 090034 OP_r0 BLANK PAGE ...
Страница 14: ...GLOSSARY AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE XII 090034 OP_r0 BLANK PAGE ...
Страница 37: ...AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM SECTION 1 SAFETY 090034 OP_r0 PAGE 19 ...
Страница 54: ...SECTION 3 SPECIFICATIONS AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE 36 090034 OP_r0 BLANK PAGE ...
Страница 69: ...AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM SECTION 4 INSTALLATION 090034 OP_r0 PAGE 51 BLANK PAGE ...
Страница 84: ...SECTION 5 OPERATION AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE 66 090034 OP_r0 BLANK PAGE ...
Страница 126: ...SECTION 7 TROUBLESHOOTING AIR IN ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE 108 090034 OP_r0 BLANK PAGE ...
Страница 130: ...SECTION 8 DIAGRAMS AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE 112 090034 OP_r0 BLANK PAGE ...
Страница 133: ...AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM SECTION 9 ILLUSTRATED PARTS LIST 090034 OP_r0 PAGE 115 NOTES ...
Страница 166: ...SECTION 9 ILLUSTRATED PARTS LIST AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE 148 090034 OP_r0 ...
Страница 174: ...APPENDIX A ADDITIONAL INFORMATION AIR N ARC 300 ALL IN ONE POWER SYSTEM PAGE 156 090034 OP_r0 BLANK PAGE ...
Страница 178: ...APPENDIX B MAINTENANCE AND SERVICE LOG AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE 160 090034 OP_r0 BLANK PAGE ...
Страница 179: ...BLANK PAGE ...