50
V-301G Series Operating Instructions Ver. 2.01E
1
You can see the head of pressure adjusting
screw from the adjusting hole on the frame
cover by pushing down the table.
2
Adjust the sealing pressure by turning the
adjusting screw using a Philips screwdriver.
3
Turning counterclockwise to the direction of H
will increase the sealing pressure.
4
Turning clockwise to the direction of L will
decrease the sealing pressure.
The optimum seal pressure varies depending on the film/pouch material and thickness. When using the machine
for the first time or the sealing is not clean after changing the pouch, please adjust the seal pressure.
11 Adjusting seal pressure
Turn
counterclockwise
(H) to increase the
pressure.
Turn clockwise
(L) to decrease
the pressure.
Push down the table fully
Warning
Always unplug the power plug before
adjusting the pressure. It is very dangerous if
the microswitch is activated without
unplugging.
Caution
Tightening or loosening the screw
excessively may damage the parts or
cause them to come apart. Carefully adjust
the sealing pressure.