V-301G Series Operating Instructions Ver. 2.01E
35
Control panel setting
Operation Procedures
Reference
1
Set a heating timer from 1 to 10 depending on the required heat time.
8-6-1 Setting the heating timer
2
Select the operation mode 2.
8-6-2 Select an operation mode
3
Set vacuum and gas timers from 1 to 9 depending on the required vacuum/
JDVÀXVKLQJOHYHO
6HWWLQJWKHYDFXXPDQGJDVÀXVK
timers
4
Move a nozzle forward by pressing a START/STOP button.
8-7 Forward a nozzle
5
Place a pouch to the seal area.
8-8 Place a pouch to the seal area
6
Push down on a table to the intermediate position.
8-9 Press down a table
7
Push a START/STOP button to start vacuuming. Vacuuming will stop after
SDVVLQJWKHVHWWLPHDQGJDVÀXVKLQJZLOOVWDUWDXWRPDWLFDOO\*DVÀXVKLQJ
also will stop automatically after passing the set time. The second vacuuming
will start.
8-10 Start/stop vacuuming and gas-
ÀXVKLQJRSHUDWLRQ
8
$IWHU¿QLVKLQJWKHVHFRQGYDFXXPLQJE\WLPHUSXVKD67$576723EXWWRQ
twice quickly. In this way you can skip the second vacuuming and a nozzle will
withdraw to the back position.
8-10 Start/stop vacuuming and gas-
ÀXVKLQJRSHUDWLRQ
9
After nozzle withdrawal, press down on a table further down to perform
sealing.
8-11 Press a table further down to seal
10
7DNHVXI¿FLHQWFRROLQJWLPH
7DNHVXI¿FLHQWFRROLQJWLPH
11
Sealing is complete.
7KH¿QLVKHGVHDO
Ŷ7LPHUYDFXXPLQJāWLPHUJDVIOXVKLQJāWLPHUYDFXXPLQJ VHDO
9-2-6 <<Vacuuming · gas-flushing · vac seal>>
Heating timer dial: 1~10
Mode selection switch: 2
Gas timer dial : 1~9
Vacuum timer dial: 1~9
Attention
After finishing the second vacuuming process, make sure to press a START/STOP button twice.
Otherwise, gas-flushing operation will start.