V-301G Series Operating Instructions Ver. 2.01E
39
V-301G
V-301G-10DK
Daily maintenance or replacement of parts at an early stage can prevent the machine from being damaged, and
keeps the machine at the optimum condition. Replace parts according to the following directions in order to
maintain your machine in optimum operating condition.
The sealing area is constructed with parts illustrated in the diagram below. When replacing parts,be careful to
arrange the parts in the same exact order.
10 Replacing the routine maintenance parts
Construction of the sealing area
Pressure lever
Silicone rubber (white)
Fluoro glass sheet
25mm-width glass tape
Sarcon sheet
13mm-width glass tape
13mm-width glass tape
Braided or ribbon
heating element
Braided or ribbon
heating element
Pressure lever
Fluoro glass sheet
25mm-width glass tape
Sarcon sheet
Ribbon heating element
13mm-width glass tape
Silicone rubber (white)
Warning
Warning
Warning
Always unplug the power plug before replacing parts. There is a danger of electrocution if it has
been done without unplugging.
Follow the directions on this manual when replacing parts. Replacing parts in the way ignoring
this manual could cause malfunction of the machine as well as electrocution and fire.
Always use only specified parts sold through
Van der Stahl Scientific
. Unspecified parts may
cause malfunction of the machine.
Always unplug the machine before maintenance.