34
V-301G Series Operating Instructions Ver. 2.01E
Control panel setting
Operation Procedures
Reference
1
Set a heating timer from 1 to 10 depending on the required heat time.
8-6-1 Setting the heating timer
2
Select the operation mode 2.
8-6-2 Selecting operation mode
3
Set vacuum and gas timers to the MANUAL position.
6HWWLQJWKHYDFXXPDQGJDVÀXVK
timers
4
Move a nozzle forward by pressing a START/STOP button.
8-7 Forward a nozzle
5
Place a pouch to the seal area.
8-8 Place a pouch to the seal area
6
Push down on a table to the intermediate position.
8-9 Press down a table
7
Push a START/STOP button to start vacuuming.
8-10 Start/stop vacuuming and gas-
ÀXVKLQJRSHUDWLRQ
8
When optimum vacuuming level is achieved, push a START/STOP button to
VWRSYDFXXPLQJ*DVÀXVKLQJRSHUDWLRQZLOOVWDUW
8-10 Start/stop vacuuming and gas-
ÀXVKLQJRSHUDWLRQ
9
:KHQRSWLPXPJDVÀXVKLQJOHYHOLVDFKLHYHGSXVKD67$576723EXWWRQ
DJDLQWRVWRSJDVÀXVKLQJ7KHVHFRQGYDFXXPLQJZLOOVWDUW
8-10 Start/stop vacuuming and gas-
ÀXVKLQJRSHUDWLRQ
10
When optimum vacuuming level is achieved, push a START/STOP button to
DJDLQWRVWRSYDFXXPLQJ7KHVHFRQGJDVÀXVKLQJZLOOVWDUW
8-10 Start/stop vacuuming and gas-
ÀXVKLQJRSHUDWLRQ
11
:KHQRSWLPXPJDVÀXVKLQJOHYHOLVDFKLHYHGSXVKD67$576723EXWWRQ
DJDLQWRVWRSJDVÀXVKLQJ$QR]]OHZLOOZLWKGUDZWRWKHEDFNSRVLWLRQ
8-10 Start/stop vacuuming and gas-
ÀXVKLQJRSHUDWLRQ
12
After nozzle withdrawal, press down on a table further down to perform
sealing.
8-11 Press a table further down to seal
13
7DNHVXI¿FLHQWFRROLQJWLPH
7DNHVXI¿FLHQWFRROLQJWLPH
14
Sealing is complete.
7KH¿QLVKHGVHDO
Ŷ
Manual vacuuming· manual gas-flushing / manual vacuuming· manual gas-flushing & seal
Heating timer dial: 1~10
Mode selection switch: 2
Gas timer dial : MANUAL
Vacuum timer dial: MANUAL