MS-350 NP Operating Instructions Ver 4.02E
26
The sealing section consists of the parts as in the illustration below. When replacing parts, be careful to arrange the
parts exactly in the same order.
Daily maintenance or replacement of parts at an early stage can prevent the machine from being damaged, and
keeps the machine at the optimum condition. Replace parts according to the following directions in order to
maintain your machine in optimum operating condition.
10 Replacing the routine maintenance parts
Structure of the sealing section
Semi-transparent tape
Pressure lever
Silicone rubber (white)
W38mm glass tape
W40mm center-dry tape
Semi transparent tape
Sarcon sheet
Heating element
Temperature sensor
W38mm glass tape
Seal receiving plate
Always unplug the machine before maintenance.
Always use only specified parts sold through
Van der Stahl Scientific
.
WARNING
▪
Always unplug the power plug before replacing parts. There is a danger of electrocution if it has been
done
without unplugging.
▪
Follow the directions on this manual when replacing parts. Replacing parts in the way ignoring this manual
could cause malfunction of the machine as well as electrocution and fire.
▪
Always use only specified parts sold through
Van der Stahl Scientific
. Unspecified parts may cause
malfunction of
the machine.