60
Revision D November 2022
7) Remove all crushed Cartridges from within the system.
8) Check to see that the Diaphragms are in usable condition. Diaphragms which are bowed
or have bent legs must be replaced.
9) Check the
gaps between Fender Panels
. The maximum gap allowed for these
overlapping parts (including Fender Panels overlapping Panels behind the system) is .78”
[20 mm] for
narrow systems
and 1.00” [25 mm] for
wide systems
. Be sure the Mushroom
Washer Assemblies are torqued to the end of the threads. If the gaps between the Fender
Panels are still too large, it may be necessary to replace bent parts.
Warning:
Fender Panel
Maximum gap allowed:
Narrow Systems
0.78” [20 mm]
Wide Systems
1.00” [25 mm]
10) Replace all crushed Cartridges (p. 38 & 56).
11) Remove damaged Nose Assembly. Attach the new Nose to the first Diaphragm using the
six (6) rail bolts, coupling nuts, rail nuts, cap screws, Pull-Out Brackets, and Bar Washers
that hold the Nose to the first Diaphragm. Adjust Nose to align with Fender Panels and
then tighten all six (6) nuts.
Warning:
Bolt Torque Requirements - p. 12
Critical Clearances
Anchor Studs above nuts – Figure 20, p. 24
Fender Panel Gap Narrow – 0.78” [20 mm]
Fender Panel Gap Wide – 1.00” [25 mm]
12) Confirm the torque of all bolts on the system (p. 12).
13) Check to be certain that the site is free from any debris.
14) The QuadGuard
®
is now ready for use.
Figure 73
Wide Systems Fender Panel Gap
Figure 72
Narrow Systems Fender Panel Gap
Содержание QuadGuard
Страница 1: ...VALTIR QuadGuard CRASH CUSHION ASSEMBLY MANUAL PN 115348 REVISION D NOVEMBER 2022...
Страница 40: ...Valtir com 39 Revision D November 2022 Wide System Identification Figure 39 Wide Systems and Model Numbers...
Страница 65: ...Valtir com 64 Revision D November 2022 Notes...
Страница 66: ...Valtir com 65 Revision D November 2022 Notes...
Страница 67: ...Valtir com 66 Revision D November 2022 Notes...
Страница 68: ......