75
Appendix D—HeatShift™System
Suggested Con
ȴ
gurations (top view)
Side wall outlets using LDK3
NOTE This duct kit may be used for outdoor
installations to reduce wall temperatures above
the unt. The discharge grilles must be located
under the weatherproof enclosure described in
the GV60CKO Outdoor Fireplace Conversion Kit
instructions.
Rear wall outlets using LDK3
Corner installations
Ʉ
WARNING
The plenum duct kits are approved
for horizontal discharge ONLY. The
termination duct plates (LDK7) are
approved for vertical upward discharge
ONLY. DO NOT install plenum or
termination plates in
ȵ
oor or ceiling. DO
NOT COVER OR PLACE objects in front of
or on top of air outlet(s). AVOID locating
outlet within 7 feet of the
ȵ
oor level as
discharge air temperatures are hot!
D O N O T D I S C H A R G E T H R O U G H
E X T E R I O R W A L L S !
Front wall outlet using LDK1, LDK4 (shown)
or LDK9
Rear wall outlet using LDK1, LDK4 (shown) or LKD9
Note: Fireplace vent may con
ȵ
ict with plenum.
O
set vent around plenum.
Top outlet using LDK7
Note: When using LDK7, the discharge
opening must be located in the same room
as the
ȴ
replace.