23
Release 07/22
2600
1500
50 MIN COVER
1000
F8 MESH - TOP FACE ONLY
50 MIN COVER
1000
450
NOTES
1. CONCRETE TO HAVE MINIMUM 28 DAY STRENGTH OF 25 MPa.
2. MINIMUM CLEAR COVER TO BE 75 mm.
3. THE AVERAGE MATERIAL-INTERNAL ANGLE OF FRICTION OVER THE DEPTH OF THE ANCHOR
WHEN MEASURED USING AN APPROVED METHODOLOGY SHALL EXCEED THE FOLLOWING:
= 20 DEGREES
Y = 12 kN/m³
Cu = 20 kPa
4. ALL UNITS ARE IN MM UNLESS NOTED OTHERWISE.
5. SAFETY CHECK ROPES ONLY REQUIRED WITH STANDARD TERMINAL.
APPROVED
DRAWN
SCALE
Rev:
NAME
DATE
CHECKED
@
ISSUE FOR
INFORMATION ONLY
C I V I L P R O D U C T S
COMPANY
valmont
A
FLEXFENCE / MASHFLEX WRSB
RECTANGULAR (TYPE 1) ANCHOR BLOCK
WR-STD-62
8
N.T.S.
A3
02-11-2011
AUSTEC
TC
02-11-2011
TC
02-11-2011
F:\ENGINEERING\SALES & MARKETING\DRAWINGS\FLEXFENCE ASSEMBLY\WR-STD-62 - TYPE 1 ANCHOR BLOCK.DWG
1
12-02-2010
INITIAL ISSUE
MS
TC
TC
2
02-11-2011
TITLE BLOCK UPDATED
DJB
TC
TC
3
08-02-2013
SAFENCE NOTE ADDED
LG
SE
LRB
4
17-10-2016
NOTE 4 ADDED
LG
SE
LG
5
13-12-2016
NOTE ADDITIONS - SOIL CONDITIONS
MC
LG
LG
6
29-10-2019
TITLE BLOCK UPDATED, NOTE 5 UPDATED
VB
LG
LG
7
01-09-2020
DIMENSION FIXED
VB
LG
LG
8
23-02-2022
NOTE NUMBER FIXED
KZ
LG
LG
Содержание INGAL MashFlex MASH TL3