BCs160VA
Nov. 15, 1997
SMART-PULP
Smart Consistency Transmitter
43
Code
A
B
C
D
E
F
G
H
I
J
K
L
SW unbleached
SW bleached
HW unbleached
HW bleached
Groundwood
RMP, TMP, CSF < 200 ml (SR > 52) 3)
RMP, TMP, CSF > 200 ml (SR < 52) 3)
Recycled fiber, OCC, unscreened
Recycled fiber, unscreened
Recycled fiber, OCC, screened
Recycled fiber, screened
CTMP
Recipe code
for pulp type
Pulp type
Pulp type codes used in Fig. 7.1b
SWU
SWB
HWU
HWB
G W
RMPL, TMPL
RMPH, TMPH
ROCCU
RCFU
ROCCS
RCFS
CTMP
Figure 7.1b Flow velocities/consistency ranges/pulp types for different sensor options
(cont. from previous page)
SMART-PULP HL
SMART-PULP JL
0 1 2 3 4 5 6 7 8
(1): For pulps C, D, E and K
(1)+(2): For pulps L, J and F
(1)+(2)+(3): For pulps A, B and G
(4) Also suitable for this zone when flow velocity
variation is max. 1:2.
(1)+(2): For pulps A and B
(1): For pulps C and D
0.7-3
0,7-3
1-3
1-3
1-4
0.7-3
0.7-3
1-3
1-5
0.7-3
1.5-6
1.5-6
(1.8-5)
(1.8-5)
1.5-4.5
1.5-5.5
(1.7-7)
(1.7-7)
1.8-7.5
1.8-7.5
1.8-7.5
1.5-6.5
(1.5-5)
1.5-8
1.8-8
3-6
3-6
(1.5-6)
(1.5-6)
1.7-6.5
1.7-6.5
1.7-5
1.5-5
1.5-7
1.7-8
(1.5-5)
2-8
2-8
4-16
4-16
5-16
5-16
5-16
5-16
4-16
4-16
5-16
4-16
1.5-6
1.5-6
1.8-6
1.8-6
3) Raw wood material; long-fibered.
To be noticed when choosing the sensor type:
Applications whose consistencies are enclosed in parentheses are not optimum
solutions in terms of the sensor for the specified pulp, but for other pulp types.
Application ranges of sensor types (% Cs)
UL LL LS GL RL WS HL JL