BCs160VA
Nov. 15, 1997
SMART-PULP
Smart Consistency Transmitter
35
5 PARTS LIST
When ordering spares, please quote this document’s number (BCs160VA) and date (Nov. 15. 1997), the
transmitter’s name (SMART-PULP), type (sensor/material options, e.g. RL/SS), model code (M1), serial
number and 2-W/3-W, and the number and name of the required part.
Example: BCs160VA, Nov. 15. 1997, SMART-PULP, RL/SS, M1 No. 960720690, 2-W, 116 RL sensor
(serial number is constructed as follows: 96 = year, 07 = week, 20690 = ordinal number).
Part
No.
Part name
Qty
Part
No.
Part name
Qty
22
27
31
32
36
37
38
39
42
76
80
81
82
90
91
93
94
96
103
105
Cover
Operator terminal
O-ring 64.5x3
O-ring 66x2
Inlet cone
Gasket seat
Diaphragm
O-ring 18.2x3
Taper pin
Special nut
O-ring 47.29x2.62
Gland packing (transmitter/
remote operator terminal)
Plug
Gasket PTFE
Retaining ring with fin
Deflector plate
O-ring 16x4
O-ring 65.09x3.53
O-ring 18x1.5
Retaining ring
1
1
1
1
1
1
1
2
1
1
1
2
1
1
1
1
1
1
3
1
106
112
113
114
115
116
117
118
120
122
123
124
125
126
127
128
129
130
131
132
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Retaining ring HL
UL sensor
JL sensor
LS sensor
GL sensor
RL sensor
WS sensor
HL sensor
LL sensor
Inlet gland
Cover with window
Remote operator terminal
case and cover
Mounting clamp assy.
Coupling
WS coupling
Blow line coupling
JL coupling, titanium
Plug
Gland packing, conn. to
control system
Remote operator terminal
TOOLS
Sensor mounting tool
Sensor removing tool
Taper pin removing tool
Calibration stand
Diagnostics weight set
1, 2 and 3 kg
275 HART® user interface
Diskette/Operating and
Installation Instructions
• When re-installing the sensor, make sure that it is
exactly parallel to the direction of flow. Check the
alignment with a ruler placed against the bottom of
the sensor’s alignment slot.
A special tool is available for aligning the sensor.
The alignment accuracy must be better than +1°.
• Finally secure the sensor’s retaining nut with
Loctite 270. Ensure that none of the locking medium
is allowed to run to the sensor’s taper assembly. Use
20 Nm torque to tighten the nut.