1 (1)
04.09.2019
Valmet MCA
Technical specification
© Valmet Automation Inc.
All rights reserved.
Measurement
Measuring range .............. 0–16 % Cs; if over 16 % Cs
consult Valmet Automation
Repeatability .................... ± 0.01 % Cs
Sensitivity ......................... 0.001 % Cs
Filtering ............................ 1–99 s
Microwave power ............. -6…+25 dBm
Pressure measurement
Measuring range .............. 0–25 bar
Accuracy .......................... ± 0.1 bar
Process conditions
pH range .......................... 2.5–11.5
Temperature ..................... 0 ≤ T < 100 °C
Process pressure
- Minimum ........................ > 1.5 bar recommended, no free
air; consult Valmet Automation
if lower
- Maximum, TB-model ...... PN25
- Maximum, FT-model ...... DIN PN16 / ANSI Class 150 /
JIS 10k
Vibration ........................... max. 20 m/s
2
, 10–2000 Hz
Process flow ..................... min 0.01 m/s
Operating environment
Temperature ..................... -20...+70 °C (-4…+158 °F),
protect from direct heat sources
Housing class ................... IP66 (NEMA 4X)
Connections
Operating power,
communication.................. cable from BRIDGE
Materials, TB sensor
Wetted parts ..................... AISI 316L (OPTION: 254 SMO),
Ceramic
Sealing rings ..................... EPDM, FKM, PTFE
Process coupling .............. AISI 316L (OPTION: 254SMO)
Mounting clamps............... AISI 304
Mounting bolts .................. 8.8 ZNE and AISI316
Materials, FT sensor
Wetted parts ..................... AISI 316, AISI 316L, Ceramic
Sealing rings ..................... EPDM, FKM
Sensor weights
MCA-TB ............................ 7.3 kg
16.1 lbs
MCA-FT 50 / 2” ................. 8.4 kg
18.5 lbs
MCA-FT 80 / 3” ................. 9.8 kg
21.6 lbs
MCA-FT 100 / 4” ............... 9.9 kg
21.8 lbs
MCA-FT 150 / 6” ............... 13.2 kg 29.1 lbs
MCA-FT 200 / 8” ............... 16.5 kg 36.4 lbs
MCA-FT 250 / 10” ............. 24.2 kg 53.4 lbs
MCA-FT 300 / 12” ............. 28.2 kg 62.2 lbs
Maximum conductivity limits for the different sensor models
Содержание K17122
Страница 1: ...Valmet Microwave Consistency Measurement Valmet MCA Installation Operating Maintenance K17122 V1 1 EN...
Страница 34: ...10 3 Menu map Operating 34 93 K17122 V1 1 EN 1 06 2020...
Страница 58: ...Advanced calibration 58 93 K17122 V1 1 EN 1 06 2020...
Страница 60: ...Advanced calibration 60 93 K17122 V1 1 EN 1 06 2020...
Страница 88: ...18 WEEE information Valmet Bridge Sensor WEEE information 88 93 K17122 V1 1 EN 1 06 2020...
Страница 91: ...2 3 Valmet MCA Spare parts Valmet Automation Inc All rights reserved 7 10 9 12 14 15 13 11...
Страница 92: ...3 3 Valmet MCA Spare parts Valmet Automation Inc All rights reserved 16 17...