Sensor installation is not allowed to
the following positions:
6.
When the sensor is installed directly
after a pump, it must be on the side
where the pump throws the pulp (see po-
sition 1 in the previous picture and the
photo on the right). In position 6 it is on
the opposite side, where the pulp flow is
not steady and cavities may form.
7.
Air pockets are likely to develop in up-
ward bends in the pipeline, and this will
disrupt the measurement because the
sensor will not always be in contact with
pulp.
Figure 12: TB model sensor installed di-
rectly after a pump.
7.2 TB sensor dimensions
TWIN BLADE
208 (8.2”)
245 (9.6”)
60
(2.4”)
80
(3.1”)
106
(4.2”)
130
(5.1”)
83 (3.3”)
155 (6.1”)
Min. 219 (8.6”)
(DN200/8”)
180 (7.1”)
L-coupling
114 (4.5”)
Figure 13: Dimensions Twin Blade.
Installation, TB model | 19 (93)