18
Overview
Corner Identification
This section briefly describes the possible VFlex
Corner Sequencing component configurations for
standard (trailing) and inverted (leading) corners.
Standard (Trailing) Corner
Orientation for all figures is based on standing
at the pivot point looking towards the LRDU or
standing at the cradle looking towards the SDU.
The Standard (Trailing) corner can use either the fixed
or swivel inlet and either the mechanical sequencing
box or the angle sensor box. See Figures 18-1 and
18-2.
Inlet Option:
Both the fixed inlet and swivel inlet
can be used with the standard (trailing) corner. See
Figures 18-1 and 18-2.
Sprinkler Rod T-Bar Mount:
Mounted on the right
side of the cradle when standing at the LRDU looking
towards the SDU. See Figures 18-1 and 18-2.
Mechanical Sequencing Box:
Used only with a
standard (trailing) corner. Sequencing box control
arm will be on the right side of the pipe at the
LRDU.
An adjustable control rod is used with the
mechanical sequencing box.
See Figure 18-1.
Angle Sensor Box:
Box is mounted with the control
rod on the right side of the pipe at the LRDU.
An
fixed control rod is used with the Angle Sensor
Box
. See Figure 18-2.
Run Cycle Box:
Mounted on the left side of the
cradle. See Figure 18-2.
Inverted (Leading) Corner
Orientation for all figures is based on standing
at the pivot point looking towards the LRDU or
standing at the cradle looking towards the SDU.
The Inverted (Leading) corner can use
ONLY
the
swivel inlet
and the
angle sensor box
.
Inlet Option:
The swivel inlet option can only be used
with the inverted (leading) corner. See Figure 18-3.
Sprinkler Rod T-Bar Mount:
Mounted on the left
side of the t-bar. See Figure 18-3.
Angle Sensor Box:
Mounted with control arm on the
left side of the pipe.
The fixed control rod must be
used with the Angle Sensor Box
. See Figure 18-3.
Run Cycle Box:
Mounted on the right side of the
cradle. See Figure 18-3.
Mechanical
Sequencing
1
3
2
5
4
6
Figure 18-1 1. Fixed Inlet
2. Sprinkler Rod T-bar Mount
3. Mechanical Sequencing Box
4. Adjustable Seq Rod
5. Control Rod Mount
6. Run Cycle Box
Electronic
Sequencing
Standard (Trailing)
2
3
1
6
4
5
Figure 18-2 1. Swivel Inlet
2. Sprinkler Rod T-bar Mount
3. Angle Sensor Box
4. Fixed Seq Rod
5. Control Rod Mount
6. Run Cycle Box
Electronic
Sequencing
Inverted (Leading)
1
3
6
2
5
4
Figure 18-3 1. Swivel Inlet
2. Sprinkler Rod T-bar Mount
3. Angle Sensor Box
4. Fixed Seq Rod
5. Control Rod Mount
6. Run Cycle Box