Installation Manual - SRF40

ENGLISH

FINISHING

WARNING

Only trim kits(s) supplied by the manufacturer 

shall be used in the installation of this appliance.

WARNING

Draft relief openings must not be covered or blocked.

NON-COMBUSTIBLE

BOARD INSTALLED

FLUSH TO THE

FIREPLACE FACING

NON-COMBUSTIBLE

BOARD

FINISHED WALL

(COMBUSTIBLE MATERIAL ALLOWED)

NON-COMBUSTIBLE 

BOARD

FINISHED WALL

(COMBUSTIBLE MATERIAL ALLOWED)

NON-COMBUSTIBLE

BOARD INSTALLED

ON THE FIREPLACE

FACING

Содержание FG00002

Страница 1: ...your gas supplier from a neighbor s phone Follow the gas supplier s instructions Ifyoucannotreachyourgassupplier callthefiredepartment Installation and service must be performed by a qualified install...

Страница 2: ......

Страница 3: ...Page 3 Installation Manual SRF40 ENGLISH To reduce the risk of fire follow the installation instructions in this manual...

Страница 4: ...replace Installation 16 3 1 Safety Information 16 3 2 Appliance Location 16 3 3 Framing Clearances and Mantle 17 3 4 Finishing 22 3 5 Installing a television above a fireplace 24 4 Venting installatio...

Страница 5: ...LISH 6 1 Control Module Access 44 6 2 Wiring Diagram 45 7 Optional Traditional Gravity Hot Air Distribution Kit Installation AC04367 47 8 Optional Modern Gravity Hot Air Distribution Kit Installation...

Страница 6: ...Page 6 Installation Manual SRF40 ENGLISH CERTIFICATION PLATE...

Страница 7: ...ividuals out of the room and away from hot surfaces 4 For appliances requiring a barrier as determined under Clause 5 15 4 A barrier designed to reduce the risk of burns from the hot viewing glass is...

Страница 8: ...e in which the appliance s connected to the venting system are located and other spaces of the building 4 Close fireplace dampers 5 Turn on clothes dryers and any appliance not connected to the ventin...

Страница 9: ...ther low areas Stay out until firefighters declare them to be safe Use your neighbor s phone and call a trained Propane Gas service person and the fire department Even though you may not continue to s...

Страница 10: ...n an area where the conditions are such that you may not detect the odor if there has been a leak of Propane Gas Odor fade due to oxidation by rust or adsorption on walls of new cylinders and tanks is...

Страница 11: ...e ANSI NFPA 70 or Canadian Electric code CSA C22 1 if an external electrical source is utilized 2 2 Qualified Installing reparing Agency Installation and replacement of gas piping gas utilization equi...

Страница 12: ...trical connections and venting should also be planned at this time Refer to the framing section to understand proper opening size of framing required for installation of the fireplace The framing of t...

Страница 13: ...ures inches water column 10 0 3 5 Burner orifice Front 56 2 25 mm Burner orifice Rear 1 55 mm 2 45 mm Efficiency 72 78 66 37 Air Shutter Opening Front Fully Open Fully Closed Air Shutter Opening Rear...

Страница 14: ...s Do not order batteries bolts screws washers or nuts They are standard hardware items and can be purchased at any local hardware store AA Battery 4x AAA Battery 3x Remote 1x Cover Plate Battery Box 1...

Страница 15: ...43 3 8 1103mm 35 890mm 43 7 8 1113mm 10mm 3 8 MIN 1 1 4 MAX 32mm 36 913mm 10 1 8 257mm 14 356mm 40 7 8 1039mm 48 7 8 1242mm 1 1 2 38mm 4 103mm 24 1 2 622mm 2021 FABRICANT DE PO LES INTERNATIONAL INC T...

Страница 16: ...ROOM DIVIDER INSTALLATION FLUSH WALL INSTALLATION ISLAND INSTALLATION CABINET INSTALLATION CORNER INSTALLATION ANGLED CORNER INSTALLATION NOTE Island and Room Divider installation is possible as long...

Страница 17: ...should be installed in the chase as per regional codes for the rest of the home Additionally in regions where cold air infiltration may be an issue the inside surfaces may be sheet rocked and taped o...

Страница 18: ...ening above the fireplace NON COMBUSTIBLE HEADER The appliance can be mounted on any of the following surfaces 1 A flat hard combustible or non combustible surface 2 A raised wooden platform 3 Four co...

Страница 19: ...617 mm 10 254 mm D 27 703 mm 12 305 mm This fireplace can be elevated off the floor provided that the fireplace is properly supported by framing materials and the ceiling clearances are maintained Fir...

Страница 20: ...a horizontal distance of 2 feet 61 cm from the center line of the terminal 18 in 46 cm 18 in 46 cm E Clearances to unventilated soffit 18 in 46 cm 18 in 46 cm F Clearance to outside corner see page 4...

Страница 21: ...in the fireplace with a header accross the top When setting the depth of the fireplace it is important to allow enough space for the facing material FOR 1 2 THICK FACING MATERIAL FOR 5 8 THICK FACING...

Страница 22: ...green topping mud sand and prep for painting When using paint or lacquer to finish the mantel the paint or lacquer must be heat resistant to prevent discolouration A full single sheet of non combustib...

Страница 23: ...lation of this appliance WARNING Draft relief openings must not be covered or blocked NON COMBUSTIBLE BOARD INSTALLED FLUSH TO THE FIREPLACE FACING NON COMBUSTIBLE BOARD FINISHED WALL COMBUSTIBLE MATE...

Страница 24: ...near a heat source If you install a television above this fireplace SBI accepts no responsibility for damage or injuries Follow the television manufacturer s installation instructions including any re...

Страница 25: ...ontal run to the outer wall flange is 16 feet the vertical dimension from the floor of the unit to the center of the termination must not be less than 9 1 2 feet EXAMPLE D Minimum Vertical and Maximum...

Страница 26: ...The horizontal vent run refers to the total length of vent pipe from the flue collar of the fireplace to the face of the outer wall Venting termination shall not be recessed into wall or siding WARNIN...

Страница 27: ...ING ABOVE 30FT 4 3 Clearance to Combustibles NOTICE Maintain one inch 1 of clearance around vertical vent pipe For horizontal vent maintain a minimum 1 inch clearance to the bottom and sides of the ve...

Страница 28: ...been approved for A Vertical installations up to 40 feet in height B Two sets of 45 degree elbow offsets within these vertical installations From 0 to a maximum of 8 ft a vent pipe can be used betwee...

Страница 29: ...tached to the vent pipe then secured with nails or screws to structural framing TWO 90 ELBOWS Example Vent Runs Initial Pipe Length A Vertical B Horizontal Maximum In Inches In Feet 12 34 3 24 30 6 36...

Страница 30: ...inimum clearances are maintained to the vent system Vertical runs of this system which pass through ceilings require the use of ONE ceiling firestop at the hole in each ceiling through which the vent...

Страница 31: ...nd secure the ceiling firestop on the ceiling side of the previously cut and framed hole If the area above the ceiling is an attic position and secure the firestop on top of the previously framed hole...

Страница 32: ...ot TWO 45 ELBOWS Note Subtract 1 1 2 feet from the total horizontal measurement for each 45 elbow installed horizontally B A Example Vent Runs Initial Pipe Length A Vertical B Horizontal Maximum In In...

Страница 33: ...4 6 Horizontal Firestops Firestops are required for safety whenever the vent system passes through an interior wall an exterior wall or a ceiling These firestops act as a firebreak heat shield and as...

Страница 34: ...allows installation depth down to 7 inch 178 mm below grade level The 7 inch 178 mm is measured from the center of the horizontal vent pipe as it penetrates through the wall Ensure the sidewall venti...

Страница 35: ...Hole After the fireplace has been positioned in its permanent location the hole through the exterior wall can be cut This hole must be 10 in 254 mm high x 10 5 8 in 270mm wide with its center line det...

Страница 36: ...th Horizontal Termination Vertical 90o Elbow To Horizontal Out The Wall 12 inch minimum rise before elbow MAXIMUM HORIZONTAL RUN 24 610 mm MAXIMUM VERTICAL RISE REQUIRED 12 305 mm MINIMUM MAXIMUM HORI...

Страница 37: ...MORE THAN 10 FEET Note that for steep roof pitches the vent height must be increased In high wind conditions nearby trees adjoining roof lines steep pitched roofs and other similar factors can result...

Страница 38: ...t to minimize draft issues between them 40 12 19M MAX 24 MINIMUM CLEARANCE TO COMBUSTIBLES NATURAL OR MAN MADE 8 2 44M MAX 8 2 44M MAX 45 45 24 MINIMUM 4 7 1 Approuved Venting Component The following...

Страница 39: ...TIBLE 9 229mm NONCOMBUSTIBLE 2 51mm D MINIMUM WIDTH FOR BACK WALL OF A RECESSED LOCATION COMBUSTIBLE 38 965mm NONCOMBUSTIBLE 24 610mm E MAXIMUM DEPTH OF 48 1219mm FOR RECESSED LOCATION ATTENTION DISCL...

Страница 40: ...ever use plastic pipe Check to confirm whether your local codes allow copper tubing or galvanized NOTICE Since some municipalities have additional local codes it is always best to consult your local a...

Страница 41: ...es must be checked for leaks by the installer This should be done with a soap solution watching for bubbles on all exposed connections and if unexposed a pressure test should be made Never use an expo...

Страница 42: ...9 kPa at the valve outlet with the inlet pressure to the valve from a minimum of 10 8 in w c 2 68 kPa for the purpose of input adjustment to a maximum of 14 0 in w c 3 484 kPa CAUTION If one of the pr...

Страница 43: ...the absence of local codes with the National Electrical Code ANSI NFPA 70 Latest Edition BLACK HOT JUNCTION BOX WHITE NEUTRAL GROUND TO JUNCTION BOX 120 VOLT POWER SUPPLY JUNCTION BOX CONNECTIONS Att...

Страница 44: ...g connector can be located inside the fireplace near the gas valve Locate and install the provided wire grommet over the low voltage battery and interface extension harnesses at the right side of the...

Страница 45: ...nction box on the right side of the fireplace to house power Replacement wire must be of the same size and type of insulation as original The appliance must be electrically connected and grounded in a...

Страница 46: ...e with other gases unless a certified kit is used WARNING Electrical Grounding Instructions This fireplace is equipped with a three prong grounding plug for your protection against shock hazard and sh...

Страница 47: ...e kit 8 rigid and flexible ducting B Dimensions of hot air outlet frame with elbow Dimensions of hot air outlet decorative grille with elbow A B C D E 18 1 2 15 1 8 10 1 4 TYP 7 3 4 TYP 1 TYP O 8 5 8...

Страница 48: ...r distribution kit is installed Hot air outlets must be installed in the same room as the fireplace Do not install either outlet in adjoining or upstairs rooms If you install the outlets at different...

Страница 49: ...on top of the fireplace Then cut and remove the insulation and the other set of knockouts inside the fireplace B Screw the 2 anchor plates E with the 8 screws provided F on the top of the fireplace 4...

Страница 50: ...ing screws 3 per elbow Insert the frames D into the outlets of the elbows C Support the frame behind the non combustible liner and screw it into place Screw the frame to the outlet of the elbow C usin...

Страница 51: ...hor plates A All screws are included Not included in the kit 8 flexible ducting Dimensions of assembled heat distribution box and adjustable decorative plate 15 11 O 8 1 8 25 44 41 1 16 A B C D AC04 4...

Страница 52: ...nstalled in the same room as the fireplace Do not install either outlet in adjoining or upstairs rooms When forced air kit is installed in conjunction with a gravity kit the forced air device will dra...

Страница 53: ...er holes on top of the fireplace Then cut and remove the insulation and the other set of knockouts inside the fireplace B Screw the 2 anchor plates E with the 8 screws provided F on the top of the fir...

Страница 54: ...cure flexible or rigid ducts B to gravity box C with self drilling screws 3 for each telescopic section Rest the housing on the non combustible material and secure with 4 screws in the housing Fix the...

Страница 55: ...lar Black Finishing Trim7 AC04325 Herringbone Brick Panels6 AC04326 Large Black Finishing Trim7 AC04328 Black Reflective Glass Panels6 AC04322 Driftwood Logs Ember and Black Glowing Wool5 AC04347 Oxfo...

Страница 56: ...com This document is available for free download on the manufacturer s website It is a copyrighted document Resale is strictly prohibited The manufacturer may update this document from time to time a...

Отзывы: