Page 43
Installation Manual - SRF40
ENGLISH
GAS / ELECTRIC
6. Electrical Connections
A factory-intalled junction box is located on the lower right side of the fireplace. Wiring must be fed to the
junction box and attached with wire nuts to the control module power leads already fed into the junction box.
CAUTION
All wiring should be done by a qualified electrician and shall be in compliance with all
local, city and state building codes. Before making the electrical connection, make
sure that the main power supply is disconnected. The fireplace, when installed, must
be electrically grounded in accordance with local codes, or in the absence of local
codes, with the National Electrical Code ANSI/NFPA 70 (Latest Edition).
BLACK (HOT)
JUNCTION BOX
WHITE (NEUTRAL)
GROUND TO JUNCTION BOX
120 VOLT POWER SUPPLY
JUNCTION BOX CONNECTIONS
• Attach black to black and white to white.
• The ground wire should be attached to the ground on the junction box.
Interface/Battery Holder:
The user interface/battery holder must be mounted within a distance allowed by the attached 12 foot
harness. As shipped, this harness is already fed through a strain relief on the bottom of the component
access box and is attached to the User Interface/Battery Holder.
NOTICE:
If an auxiliary device is to be used, its wiring may be fed through the junction box strain relief.
Auxiliary device amperage limit is 5 amps.
NOTICE:
A one inch diameter hole should be use to pass wiring through studs.