GAS / ELECTRIC
5.3 Checking Manifold Pressures
Both Propane and Natural Gas valves have a built-in pressure regulator in the gas valve.
Natural Gas models will have a manifold pressure of approximately 3.5 in w.c. (0.871 kPa) at the valve
outlet with the inlet pressure to the valve from a minimum of 4.5 in w.c. (1.120 kPa) for the purpose of
input adjustment to a maximum of 14.0 in w.c. (3.484 kPa).
Propane Gas models will have a manifold pressure approximately 10.0 in w.c. (2.49 kPa) at the valve
outlet with the inlet pressure to the valve from a minimum of 10.8 in w.c. (2.68 kPa) for the purpose of
input adjustment to a maximum of 14.0 in w.c. (3.484 kPa).
CAUTION
If one of the procedures results in pressures in excess of 1/2 psig (14 in w.c.) (3.5 kPa)
on the fireplace gas valve, it will result in a hazardous condition.
GAS VALVE
OUTLET
PRESSURE
TAP
INLET
PRESSURE
TAP
5.4 Gas Line Connection
Remove the access panel from the right side of the fireplace to access the gas valve, gas flex line,
junction box, and system wiring.
Attach the gas flex line to the pre-installed gas line. Refer to the Gas Supply section in this manual for
details on the installation requirements for the gas supply line.