Chapter 5 _______________________________________________ Wiring and Power Management
VAISALA_______________________________________________________________________ 59
The signal names Data in (RxD) and Data out (TxD) in the table
describe the direction of data flow as seen from the transmitter.
Table 5
Screw Terminal Pin-outs
Screw
terminal
RS-232
SDI-12
RS-485
RS-422
10 HTG- Vh- (heating)
Vh- (heating)
Vh- (heating)
Vh- (heating)
9 HTG+ Vh+ (heating)
Vh+ (heating)
Vh+ (heating)
Vh+ (heating)
8 SGND GND for data
GND for data
GND for data
GND for data
7 RXD
Data in (RxD)
Data in (Rx)
-
-
6 TX+
-
-
Data+
Data out (TX-)
5 TX-
Data out (TxD) Data out (Tx)
Data -
Data out (TX+)
4 RX+
-
-
-
Data in (Rx+)
3 RX-
-
-
-
Data in (Rx-)
2 VIN-
Vin-
(operating)
Vin-
(operating)
Vin-
(operating)
Vin-
(operating)
1 VIN+
Vin+
(operating)
Vin+
(operating)
Vin+
(operating)
Vin+
(operating)
NOTE
Ground the external wiring shield. The shield is not connected inside
WXT.
NOTE
In true SDI-12, Data in (Rx) and Data out (Tx) lines must be combined.
NOTE
Short circuit loops are required between terminals 3 & 5, and
4 & 6 for RS-485. See
.