Chapter 3 ______________________________________________________ Functional Description
VAISALA_______________________________________________________________________ 35
The heating control tries to keep Th at +15 °C by adjusting the heating
power. The heater control switches heating resistors on and off based on
heating voltage and Th.
The instant current depends on the heater voltage. You must select the
power supply with the instant current in mind. The average (5s) heating
power and heater performance do not depend on the heating voltage.
When the heating function is disabled, the heating is off in all
conditions. See
Supervisor Message on page 144
Table 2
Heater Resistance
Transmitter model
Heater resistance
when Vh < 15 V
Heater resistance
when Vh > 15 V
WXT536
WXT535
WXT533
WXT532
15
57
WXT531
27
NOTE
Snow accumulation can cause temporary wind measurement problems
even when heating is enabled.