User’s Guide ______________________________________________________________________
42 __________________________________________________________________ M211840EN-C
Installing the Transmitter
At the measurement site, you must mount, ground, align, and connect
the transmitter to the data logger and the power source.
Mounting
The transmitter is easy to install as it does not have any moving parts.
The transmitter can be mounted onto
-
vertical pole mast
-
horizontal cross arm
WARNING
To protect personnel and the device, install a lightning rod with the tip
at least one meter above the transmitter. The rod must be properly
grounded, compliant with all applicable local safety regulations.
NOTE
Install the transmitter upright.
NOTE
The transmitter radiation shield reflects light. If you install the
transmitter next to a pyranometer, the pyranometer can give incorrect
measurements. Install the transmitter on the same level with the
pyranometer so that the distance between the units is 70 ... 80 cm
(27 ... 31 in).