0020257297_06 Installation and maintenance instructions
77
Technical data
–
Refrigerant circuit
VWL 35/5
AS 230V
(S2)
VWL 55/5
AS 230V
(S2)
VWL 75/5
AS 230V
(S2)
VWL 105/5
AS 230V
(S2)
VWL 105/5
AS (S2)
VWL 125/5
AS 230V
(S2)
VWL 125/5
AS (S2)
Material, refrigerant pipe
Copper
Copper
Copper
Copper
Copper
Copper
Copper
Basic length, refrigerant
pipe, minimum
3 m
3 m
3 m
3 m
3 m
3 m
3 m
Basic length of the refriger-
ant pipe, maximum, outdoor
unit above indoor unit
40 m
40 m
40 m
40 m
40 m
40 m
40 m
Permissible height differ-
ence, outdoor unit above the
indoor unit
30 m
30 m
30 m
30 m
30 m
30 m
30 m
Basic length of the refriger-
ant pipe, maximum, indoor
unit above outdoor unit
25 m
25 m
25 m
25 m
25 m
25 m
25 m
Permissible height differ-
ence, indoor unit above the
outdoor unit
10 m
10 m
10 m
10 m
10 m
10 m
10 m
Connection technology, re-
frigerant pipe
Flare
connection
Flare
connection
Flare
connection
Flare
connection
Flare
connection
Flare
connection
Flare
connection
Outer diameter, hot gas pipe
1/2 "
(12.7 mm)
1/2 "
(12.7 mm)
5/8"
(15.875 mm)
5/8"
(15.875 mm)
5/8"
(15.875 mm)
5/8"
(15.875 mm)
5/8"
(15.875 mm)
Outer diameter, liquid pipe
1/4"
(6.35 mm)
1/4"
(6.35 mm)
3/8"
(9.575 mm)
3/8"
(9.575 mm)
3/8"
(9.575 mm)
3/8"
(9.575 mm)
3/8"
(9.575 mm)
Minimum wall thickness, hot
gas pipe
0.8 mm
0.8 mm
0.95 mm
0.95 mm
0.95 mm
0.95 mm
0.95 mm
Minimum wall thickness,
liquid pipe
0.8 mm
0.8 mm
0.8 mm
0.8 mm
0.8 mm
0.8 mm
0.8 mm
Refrigerant, type
R410A
R410A
R410A
R410A
R410A
R410A
R410A
Refrigerant, fill quantity
1.50 kg
1.50 kg
2.39 kg
3.60 kg
3.60 kg
3.60 kg
3.60 kg
Refrigerant, Global Warming
Potential (GWP)
2088
2088
2088
2088
2088
2088
2088
Refrigerant, CO
2
equivalent
3.13 t
3.13 t
4.99 t
7.52 t
7.52 t
7.52 t
7.52 t
Permissible operating pres-
sure, maximum
4.15 MPa
(41.50 bar)
4.15 MPa
(41.50 bar)
4.15 MPa
(41.50 bar)
4.15 MPa
(41.50 bar)
4.15 MPa
(41.50 bar)
4.15 MPa
(41.50 bar)
4.15 MPa
(41.50 bar)
Compressor, type
Rotary
piston
Rotary
piston
Rotary
piston
Rotary
piston
Rotary
piston
Rotary
piston
Rotary
piston
Compressor, oil type
Specific
polyvinyl
ether (PVE)
Specific
polyvinyl
ether (PVE)
Specific
polyvinyl
ether (PVE)
Specific
polyvinyl
ether (PVE)
Specific
polyvinyl
ether (PVE)
Specific
polyvinyl
ether (PVE)
Specific
polyvinyl
ether (PVE)
Compressor, control
Electronic
Electronic
Electronic
Electronic
Electronic
Electronic
Electronic
Technical data
–
Application limits, heating mode
VWL 35/5
AS 230V
(S2)
VWL 55/5
AS 230V
(S2)
VWL 75/5
AS 230V
(S2)
VWL 105/5
AS 230V
(S2)
VWL 105/5
AS (S2)
VWL 125/5
AS 230V
(S2)
VWL 125/5
AS (S2)
Air temperature, minimum
−
20
℃
−
20
℃
−
20
℃
−
20
℃
−
20
℃
−
20
℃
−
20
℃
Air temperature, maximum
20
℃
20
℃
20
℃
20
℃
20
℃
20
℃
20
℃
Air temperature, minimum,
during domestic hot water
generation
−
20
℃
−
20
℃
−
20
℃
−
20
℃
−
20
℃
−
20
℃
−
20
℃
Air temperature, maximum,
during domestic hot water
generation
43
℃
43
℃
43
℃
43
℃
43
℃
43
℃
43
℃
Technical data
–
Application limits, cooling mode
Validity:
Product with cooling mode
VWL 35/5
AS 230V
(S2)
VWL 55/5
AS 230V
(S2)
VWL 75/5
AS 230V
(S2)
VWL 105/5
AS 230V
(S2)
VWL 105/5
AS (S2)
VWL 125/5
AS 230V
(S2)
VWL 125/5
AS (S2)
Air temperature, minimum
15
℃
15
℃
15
℃
15
℃
15
℃
15
℃
15
℃
Air temperature, maximum
46
℃
46
℃
46
℃
46
℃
46
℃
46
℃
46
℃
Содержание VWL 105/5 AS S2