58
Installation and maintenance instructions 0020257297_06
▶
Route the hydraulic lines and electrical wires.
▶
Provide a wall duct.
4.8
Ground installation
4.8.1
Creating a foundation
Validity:
Region with ground frost
800
200
540
200
1400
Ø100
270
300
100
AB
106
2
3
4
1
▶
Dig a hole in the ground. The recommended dimen-
sions can be found in the figure.
▶
Insert a downpipe
(1)
.
▶
Insert a layer of coarse rubble
(3)
. Calculate the depth
(A)
in accordance with local conditions.
–
Minimum depth: 900 mm
▶
Calculate the height
(B)
in accordance with local condi-
tions.
▶
Create two concrete strip foundations
(4)
. The recom-
mended dimensions can be found in the figure.
▶
Place a gravel bed
(2)
between and beside the strip
foundations.
4.8.2
Installing the product
Validity:
Small damping feet
▶
Use the small damping feet from the accessories.
▶
Align the product horizontally.
Validity:
Large damping feet
▶
Use the large damping feet from the accessories.
▶
Align the product horizontally.
Validity:
Raised base
▶
Use the raised base and the small damping feet from
the accessories.
▶
Align the product horizontally.