Installation instructions geoTHERM VWS/VWW 0020051574_01
90
Appendix
Heat pump schematic - VWS
7
9
3
T2
10
8
6
T3
T8
11
12
13
14
M
T1
1
2
4
5
15
T4
T5
T6
Fig. 1, Appendix, Heat pump schematic - VWS
Key to Fig. 1, Appendix
Heat pump components
1 High pressure sensor
2 High pressure switch
3 Compressor
4 Low pressure sensor
5 Low pressure switch
6 Heat source circuit pressure sensor
7 Evaporator
8 Expansion
Valve
9 Condenser
10 Filter drier
15 Heating circuit pressure sensor
To be provided on the customer side
11 DHW return line
12 3 way diverter valve
13 Heating return
14 Heating hot water