48
Installation and maintenance instructions ecoTEC exclusive 0020193968_05
Code
Parameter
Values
Unit
Increment, select, explanation
Factory
setting
Own
setting
Min.
Max.
D.005
Heating target flow temper-
ature
Current value
°C
Target flow temperature value (or
target return value)
–
Not ad-
justable
D.006
Outlet temperature target
value
Current value
°C
Domestic hot water temperature
target value (only products with in-
tegrated domestic hot water gener-
ation)
–
Not ad-
justable
D.007
Cylinder temperature tar-
get value
Comfort mode target value
Current value
°C
Only products with integrated do-
mestic hot water generation
Only products with no integrated
domestic hot water generation and
with a connected cylinder
–
Not ad-
justable
D.008
Controller 3-4
Current value
–
0: Open (Room thermostat at ter-
minal RT open = No heat require-
ment)
1: Closed (Room thermostat at ter-
minal RT closed = Heat require-
ment)
–
Not ad-
justable
D.009
eBUS controller target
value
Current value
–
Target value from external eBUS
controller
–
Not ad-
justable
D.010
Internal pump
Current value
–
0: Off
1: On
–
Not ad-
justable
D.011
External pump
Current value
–
0: Off
1: On
–
Not ad-
justable
D.012
Cyl. charging pump
Current value
–
0: Off
1: On
–
Not ad-
justable
D.013
Circulation pump
Current value
–
0: Off
1: On
–
Not ad-
justable
D.014
Pump speed target value
Current value
%
Target value of internal high-effi-
ciency pump. Possible settings:
0 = Auto
1 = 53
2 = 60
3 = 70
4 = 85
5 = 100
0 = Auto
D.015
Pump speed actual value
Current value
%
High-efficiency pump
–
Not ad-
justable
D.016
Controller 24 V DC: Heat-
ing mode
Current value
–
Heating mode
0: Off
1: On
–
Not ad-
justable
D.017
Control type
0
1
–
Heating flow/return temperature
control changeover
0: Flow
1: Return (conversion for underfloor
heating)
If you have activated the return
temperature control, the function
for automatically limiting the heat
output using the volume flow re-
mains active. The partial heat load
that is selected under
D.000
(
auto
= max.) continues to be the upper
limit.
0