Appendix
24
Installation and maintenance instructions ecoPOWER 3.0 /2, ecoPOWER 4.7 /2 0020241403_02
Fault code (20-digit*)
Description
1
2
3
4
5
–
8
9
–
12
13
–
16
17
–
20
E1
8
Too many motor electronic system communication faults
E1
1
Safety chain
E1
2
Flue gas counter pressure
E1
4
Coolant temperature > 110 °C
E1
8
Flue gas temperature > 116 °C
* Blank spaces are shown in the display with the value 0
Control process fault
Fault code (20-digit*)
Description
1
–
4
5
6
7
8
9
–
12
13
–
16
17
–
20
E7
1
Temperature sensor for the product's return
E0
2
Back-up boiler temperature sensor
E5
4
Gas pressure too low during operation
E5
8
Motor false start
E5
1
Power start false start
E0
2
MODBUS
E7
4
CHP system temperature sensor
E5
8
Enable motor electronic system
E5
1
Switch off motor
E3
2
Coupling time exceeded
E7
4
Motor compartment temperature > 100 °C
8
Reserve
E7
1
Inverter locked
2
Reserve
E3
4
Inverter communication
E5
8
Motor electronics communication
* Blank spaces are shown in the display with the value 0
Inverter fault
Fault code (20-digit*)
Description
1
–
4
5
–
8
9
10
11
12
13
–
16
17
–
20
E3
1
Direct current link voltage too low
E3
2
Direct current link voltage too high
E6
4
Network frequency too high
E6
8
Network frequency too low
E6
1
Network voltage too high
E6
2
Network voltage too low
E6
4
Network synchronisation
E3
8
Inverter power
E6
1
IGBT temperature too high
E6
2
Power module
E3
4
Low speed
E3
8
Overspeed
E3
1
Control process communication
E6
2
Average network voltage too high
E6
4
Self-test
E1
8
No rotating field for mains voltage
* Blank spaces are shown in the display with the value 0