23
6.2.2 Air
supply
For a trouble free and satisfactory operation of the pneumatic components in the Oilcon
®
Oil
Discharge Monitoring and Control System a supply of clean, dry air at a constant pressure is
essential.
Air supply conditions EPU
Valve control
4,0 bar nom., 7 bar max. (0,4 MPa nom., 0,7 MPa max.)
Window wash pump
4,0 bar nom., 7 bar max. (0,4 MPa nom., 0,7 MPa max.)
Average consumption
6 l/min
Maximum consumption
50 l/min
6.2.3 Electrical
supply
Electrical supply conditions
Main Control Unit
24 VDC – 0,1 A
Emergency supply
24 VDC – 0,1 A
Electro Pneumatic Unit
115/230 VAC 50/60 Hz, 0,5 A
Sample pump motor
3 phase 380–420 VAC, 50 Hz, 1.1 kW, 2.5 A
or 3 phase 440–480 VAC, 60 Hz, 1.3 kW, 2.5 A
NOTE:
AS REQUIRED BY REGULATIONS THE EMERGENY POWER SUPPLY HAS TO
ORIGINATE FROM A SOURCE INDEPENDENT FROM THE SOURCE OF THE MAIN
POWER SUPPLY.
6.3 PIPEWORK
GENERAL
All pipework for water services should be of a suitable material and capable of withstanding working
pressures of up to 16 bar. The pipework has been standardised at 15 mm O.D. with a minimum wall
thickness of 1 mm. For example: ASTM B111-69 alloy 706 - or BS 378/2871 type CN 102-0.
Air signal pipework should be copper, and generally be 6 mm O.D. x 4 mm I.D.
The exception in this sizing is the air supply for the window wash pump mounted on the skid, and
shown as V12. These lines are 8 mm O.D. x 6 mm I.D. (ASTM B75-68 alloy 122 - or BS 2871/1971
type C106-0).
Pipework must be clean and oil free prior to fitting and care must be taken to ensure all joints are
leak tight. Failure to ensure this will adversely affect system function, particularly if air leakage is
evident on pump suction lines. Ideally all joints should be made using brazed couplings. If piping is
being installed during a sea passage then compression fittings may be used. These couplings
should be of a salt water resistant material, and the use of stainless steel compression rings may be
necessary if a non-flared tube end technique is used to make the joints. Mild steel couplings must
not be used. Pipework must be adequately clipped and supported, and shall not impose any strain
or force on equipment, e.g. pump or skid assembly. Pipework must also be protected in exposed
situations. In those cases where the water discharge from the ballast skid is taken to a slop tank, if
the ship has an inert gas system, a loop-seal arrangement must be fitted in the discharge line to
prevent contamination being forced back down the line. Also measures must be taken to prevent the
discharge from free-falling into the tank. This is usually achieved by diverting the flow against the
bulkhead of the tank.
Содержание OILCON MARK 6M
Страница 112: ...111...
Страница 113: ...112...
Страница 114: ...113...
Страница 115: ...114...
Страница 116: ...115...
Страница 117: ...116...
Страница 118: ...117...
Страница 119: ...118...
Страница 120: ...119...
Страница 121: ...120...
Страница 122: ...121...
Страница 123: ...122...
Страница 124: ...123...
Страница 125: ...124...
Страница 128: ...127 Drawing 1 0806 0005 Sheet 1 2...
Страница 129: ...128 Drawing 2 0806 0005 Sheet 2 2...
Страница 130: ...129 Drawing 3 0806 1041...
Страница 131: ...130 Drawing 4 0806 1075...
Страница 132: ...131 Drawing 5 0806 1076...
Страница 133: ...132 Drawing 6 0806 1077...
Страница 134: ...133 Drawing 7 0806 1260 Sheet 1 2...
Страница 135: ...134 Drawing 8 0806 1260 Sheet 2 2...
Страница 136: ...135 Drawing 9 0806 1265...
Страница 137: ...136 Drawing 10 0806 1267...
Страница 138: ...137 Drawing 11 0806 1268...
Страница 139: ...138 Drawing 12 0806 1279...
Страница 140: ...139 Drawing 13 0806 1285...
Страница 141: ...140 Drawing 14 0806 1286...
Страница 142: ...141 Drawing 15 0806 1287...
Страница 143: ...142 Drawing 16 0806 1288...
Страница 144: ...143 Drawing 17 0806 1621...
Страница 145: ...144 Drawing 18 0806 1622...
Страница 146: ...145 Drawing 19 0806 2032...
Страница 147: ...146 Drawing 20 0806 2048...
Страница 148: ...147 Drawing 21 0806 2050...
Страница 149: ...148 Drawing 22 0806 5019...
Страница 150: ...149 Drawing 23 0806 5026...
Страница 151: ...150 Drawing 24 0806 8016...
Страница 152: ...151 Drawing 25 0806 8023...
Страница 153: ...152 Drawing 26 0806 8035...
Страница 154: ...153 Drawing 27 0806 8038 Sheet 1 4...
Страница 155: ...154 Drawing 28 0806 8038 Sheet 2 4...
Страница 156: ...155 Drawing 29 0806 8038 Sheet 3 4...
Страница 157: ...156 Drawing 30 0806 8038 Sheet 4 4...
Страница 158: ...157 Drawing 31 0806 8039...
Страница 159: ...158 Drawing 32 0806 8040...
Страница 160: ...159 Drawing 33 0806 8070...
Страница 161: ...160 Drawing 34 0810 2010...
Страница 162: ...161 Drawing 35 0871 1213...
Страница 163: ...162 Drawing 36 0899 1092...
Страница 164: ...163 Drawing 37 0899 1163...
Страница 165: ...164 Drawing 38 0899 1249...
Страница 166: ...165 Drawing 39 0899 1256...
Страница 167: ...166 Drawing 40 0899 1258...
Страница 168: ...167 Drawing 41 0899 1259...