TECHNICAL DATA
vacon • 17
4.1.4
Vacon NXC Regenerative low harmonic drives – Mains voltage 525—690 V
High overload = Max current IS, 2 sec/20 sec, Rated overload current, 1 min/10 min
Following continuous operation at rated output current, rated overload current
for 1 min, followed by a period of load current less than rated current, and of
such duration that the r.m.s output current, over the duty cycle, does not exceed
rated output current (IH)
Low overload = Max current IS, 2 sec/20 sec, Rated overload current, 1 min/10 min
Following continuous operation at rated output current, rated overload current
for 1 min, followed by a period of load current less than rated current, and of
such duration that the r.m.s output current, over the duty cycle, does not exceed
rated output current (IL)
Mains voltage 525-690 V, 50/60 Hz, 3~
Frequency
converter
type
Loadability
Motor shaft
power
Frame
Dimensions and
weight*
WxHxD/kg
Low
High
690V supply
Rated
contin.
current I
L
(A)
Rated
overload
current
(A)
Rated
contin.
current I
H
(A)
50%
overload
current
(A)
Max
current
I
S
Low
overload
P(kW)
High
overload
P(kW)
NXC0125 6
125
138
100
150
200
110
90
FI9+FI9
606x2275x605/371
NXC0144 6
144
158
125
188
213
132
110
FI9+FI9
606x2275x605/371
NXC0170 6
170
187
144
216
245
160
132
FI9+FI9
606x2275x605/371
NXC0208 6
208
229
170
255
289
200
160
FI9+FI9
606x2275x605/371
NXC0261 6
261
287
208
312
375
250
200
FI10+FI10
606x2275x605/341
NXC0325 6
325
358
261
392
470
315
250
FI10+FI10
606x2275x605/371
NXC0385 6
385
424
325
488
585
355
315
FI10+FI10
606x2275x605/371
NXC0416 6
416**
416**
325
488
585
400**
315
FI10+FI10
606x2275x605/403
NXC0460 6
460
506
385
578
693
450
355
FI12
806x2275x605/524
NXC0502 6
502
552
460
690
828
500
450
FI12
806x2275x605/524
NXC0590 6
590**
649**
502**
753**
904**
560**
500**
FI12
806x2275x605/577
NXC0650 6
650
715
590
885
1062
630
560
FI12
1206x2275x605/745
NXC0750 6
750
825
650
975
1170
710
630
FI12
1206x2275x605/745
NXC0820 6
820**
902**
650
975
1170
800**
630
FI12
1206x2275x605/745
NXC0920 6
920
1012
820
1230
1410
900
800
FI13+FI13
1406x2275x605/1000
NXC1030 6
1030
1130
920
1380
1755
1000
900
FI13+FI13
1406x2275x605/1000
NXC1180 6
1180**
1298**
1030**
1463**
1755** 1150**
1000**
FI13+FI13
1406x2275x605/1000
NXC1500 6
1500
1650
1300
1950
2340
1500
1300
FI14
2406X2275X605/2350
NXC1900 6
1900
2090
1500
2250
2700
1800
1500
FI14
2806X2275X605/2440
NXC2250 6
2250
2475
1900
2782
3335
2000
1800
FI14
2806X2275X605/2500
Table 4-4. Power ratings and dimensions of Vacon regenerative low-harmonic drives, supply voltage 525-690V.
Note: The rated currents in given ambient temperatures are achieved only when the switching
frequency is equal to or less than the factory default (automatic thermal management).
*The dimensions indicated are for the basic regenerative low-harmonic IP21 version of the converter
cabinet. Some options increase the width, height or weight of the cabinet. Check the delivery specific
documentation for more details.
** Maximum ambient tempe35°C