TECHNICAL DATA
4
4.2.2
Vacon NX_6 – Mains voltage 525—690 V
High overload = Max current IS, 2 sec/20 sec, 150% overloadability, 1 min/10 min
Following continuous operation at rated output current, 150 % rated output current (IH)
for 1 min, followed by a period of load current less than rated current, and of such
duration that the r.m.s output current, over the duty cycle, does not exceed rated
output current (IH)
Low overload = Max current IS, 2 sec/20 sec, 110% overloadability, 1 min/10 min
Following continuous operation at rated output current, 110% rated output current (IL)
for 1 min, followed by a period of load current less than rated current, and of such
duration that the r.m.s output current, over the duty cycle, does not exceed rated
output current (IL)
All sizes are available as IP21/NEMA1 Sizes FR4 to FR10 are additionally available as IP54/NEMA12.
FR12 is available only as NXP.
Mains voltage 525-690 V, 50/60 Hz, 3~
AC drive
type
Loadability
Motor shaft power
Frame
Dimensions and
weight
WxHxD/kg
(in/lb)
Low
High
690V supply
575V supply
Rated
continuous
current I
L
(A)
10%
overload
current
(A)
Rated
continuous
current I
H
(A)
50%
overload
current
(A)
Max
current
I
S
10%
overload
104 °F
P(HP)
50%
overload
122 °F
P(HP)
10%
overload
104 °F
P(hp)
50%
overload
122 °F
P(hp)
NX_ 0004 6
4.5
5.0
3.2
4.8
6.4
4
3
3.0
2.0
FR6
7.7x20.4x9.3/40.8
NX_ 0005 6
5.5
6.1
4.5
6.8
9.0
5.4
4
3.0
3.0
FR6
7.7x20.4x9.3/40.8
NX_ 0007 6
7.5
8.3
5.5
8.3
11.0
7.4
5.4
5.0
3.0
FR6
7.7x20.4x9.3/40.8
NX_ 0010 6
10
11.0
7.5
11.3
15.0
10
7.4
7.5
5.0
FR6
7.7x20.4x9.3/40.8
NX_ 0013 6
13.5
14.9
10
15.0
20.0
13
10
11
7.5
FR6
7.7x20.4x9.3/40.8
NX_ 0018 6
18
19.8
13.5
20.3
27
20
13
15
11
FR6
7.7x20.4x9.3/40.8
NX_ 0022 6
22
24.2
18
27.0
36
25
20
20
15
FR6
7.7x20.4x9.3/40.8
NX_ 0027 6
27
29.7
22
33.0
44
29.4
25
25
20
FR6
7.7x20.4x9.3/40.8
NX_ 0034 6
34
37
27
41
54
40
29.4
30
25
FR6
7.7x20.4x9.3/40.8
NX_ 0041 6
41
45
34
51
68
50
40
40
30
FR7
9.3x23.3x10.1/77.2
NX_ 0052 6
52
57
41
62
82
60
50
50
40
FR7
9.3x23.3x10.1/77.2
NX_ 0062 6
62
68
52
78
104
74
60
60
50
FR8
11.5x29.8x13.5/128
NX_ 0080 6
80
88
62
93
124
101
74
75
60
FR8
11.5x29.8x13.5/128
NX_ 0100 6
100
110
80
120
160
121
101
100
75
FR8
11.5x29.8x13.5/128
NX_ 0125 6
125
138
100
150
200
147
121
125
100
FR9
18.9x45.3x14.3/322
NX_ 0144 6
144
158
125
188
213
177
147
150
125
FR9
18.9x45.3x14.3/322
NX_ 0170 6
170
187
144
216
245
214
177
150
150
FR9
18.9x45.3x14.3/322
NX_ 0208 6
208
229
170
255
289
268
214
200
150
FR9
18.9x45.3x14.3/322
NX_ 0261 6
261
287
208
312
375
335
268
250
200
FR10
23.4x79.4x23.7/749.6
NX_ 0325 6
325
358
261
392
470
422
335
300
250
FR10
23.4x79.4x23.7/749.6
NX_ 0385 6
385
424
325
488
585
476
422
400
300
FR10
23.4x79.4x23.7/749.6
NX_ 0416 6
416
458
325
488
585
536
422
450
300
FR10
23.4x79.4x23.7/749.6
NX_ 0460 6
460
506
385
578
693
603
476
450
400
FR11
31.3x79.4x23.7/882
NX_ 0502 6
502
552
460
690
828
670
603
500
450
FR11
31.3x79.4x23.7/882
NX_ 0590 6
590
649
502
753
904
751
670
600
500
FR11
31.3x79.4x23.7/1036
NXP 0650 6
650
715
590
885
1062
845
751
650
600
FR12
47.6x79.4x23.7/1323
NXP 0750 6
750
825
650
975
1170
952
845
800
650
FR12
47.6x79.4x23.7/1323
NXP 0820 6
820
902
650
975
1170
1072
845
800
650
FR12
47.6x79.4x23.7/1323
Table 4-2. Power ratings and dimensions of Vacon NX_, supply voltage 525—690V.
Note: The rated currents in given ambient temperatures are achieved only when the switching frequency is equal to
or less than the factory default.
Note: The rated currents for FR10 to FR12 are valid at an ambient temperature of 104 F (except for 0416 6, 0590 6
and 0820 6: rated currents valid at an ambient temperature of 95 °F).
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]