background image

Keypad Remote Control Options

Installation Manual

DPD00109

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Содержание DPD00109

Страница 1: ...Keypad Remote Control Options Installation Manual DPD00109 Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...

Страница 2: ... following the steps outlined below Option Kit Contents The option kits include the following materials NOTES 1 Only one will be used 2 To mount the keypad interface board into the proper keypad interface housing 3 To mount the remote keypad assembly into the host enclosure For the XRKWM and the XRKMK customers must supply shielded cable Belden 22418 or the equivalent is suggested Fifteen circuits...

Страница 3: ... bus capacitors discharge Ensure that any other power sources that may feed control logic have been disconnected DO NOT short across DC bus capacitors or touch unshielded components or terminal strip screw connections with voltage present Install all covers before applying power or starting and stopping the drive The user is responsible for conforming to all applicable code requirements with respe...

Страница 4: ...Keypad Remote Control Options vacon 5 Figure 1 Dimensions of Remote Keypad Kit Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...

Страница 5: ...cure the keypad assembly and retain these for future use These are M4 x 10 screws 4 Remove the keypad assembly It will not be used in the final assembly but may be useful as a replacement part in another unit If you will be storing it for a long period of time re use the static bag that the remote keypad assembly came in For the XRKPM perform steps 3 5 beginning on page 7 For the XRKWM perform ste...

Страница 6: ...e applied to 6 in lb maximum 4 Remove the adhesive covering liner from the overlay 5 Align and adhere the overlay to the front side of the keypad module Press the part down firmly to ensure adequate adhesion to the plastic housing 6 Fasten a cable clamp to the outside of the overlay Positioning aids are visible on the surface 7 Connect the ribbon cable to the interface board through the opening in...

Страница 7: ...e to 12 in lb maximum 3 Make sure that all cabling is routed so that it is not pinched in the assembly The ribbon cable should be routed through the opening in the cover and should exit downward 4 If or when you re install the cover route the ribbon cable through the opening and limit the installation torque on the cover screws to 26 in lb maximum Figure 4 Re assembling the AC Drive XRKPM Option P...

Страница 8: ... to the host enclosure Connect the ribbon cable to the J1 connector and route it through the cable clamp The cable should exit the keypad module downward 4 Route the cabling as needed to avoid any damage Additional cable clamps are provided to allow strain relief for the wire Figure 5 Installing the Remote Keypad Assembly into the Host Enclosure XRKPM Option For detailed information on using the k...

Страница 9: ...ed to 6 in lb maximum 4 Remove the adhesive covering liner from the overlay 5 Align and adhere the overlay to the front side of the keypad module Press the part down firmly to ensure adequate adhesion to the plastic housing 6 Install the tie wrap provided in the lower portion of the interface board Connect the customer supplied 15 conductor cable within the tie wrap and terminate to TB1 and TB2 No...

Страница 10: ...in lb maximum 3 Make sure that all cabling is routed so that it is not pinched in the assembly The multi conductor must be routed through an unused conduit entry Be sure to use the appropriate conduit fittings for your environment 4 When you re install the cover required for NEMA 4X IP66 integrity limit the installation torque on the four 4 screws to 26 in lb maximum Figure 7 Re assembling the AC ...

Страница 11: ...to loosen the cable clamp to install the cable in it 4 Terminate the individual wires to TB1 and TB2 as in Step 6 6 For your convenience TB1 and TB2 terminal blocks are removable 5 Route the cabling as needed to avoid any damage Additional wire ties and tie bases are provided to allow strain relief for the wire Figure 8 Installing the Remote Keypad Assembly into the Host Enclosure XRKWM Option For...

Страница 12: ...and open the cover 3 Remove the four 4 screws that secure the keypad assembly and retain these for future use These are M5 x 12 screws 4 Unplug the ribbon cable and remove the keypad assembly It will be re used in Step 12 5 Now go on to Step 10 beginning on page 14 Figure 9 Removing the Keypad Assembly XRKMK Option Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...

Страница 13: ...lamp to install the cable in it 5 Terminate the individual wires to TB1 and TB2 as in Step 6 6 Note the wire color assignments this will be useful in Step 12 For your convenience TB1 and TB2 terminal blocks are removable 6 Secure the cable shield s to Terminal 1 7 Route the cabling as needed to avoid any damage The multi conductor must be routed through an unused conduit entry Be sure to use appro...

Страница 14: ...low 2 Insert the keypad interface board onto the rear of the keypad assembly being sure to engage the connector stacker simultaneously 3 Fasten the keypad interface assembly with five 5 M3 5 x 10 screws along with the loop clamp provided Limit installation torque to 12 in lb maximum Figure 11 Assembling the Remote Keypad Interface XRKMK Option Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com...

Страница 15: ...to loosen the cable clamp to install the cable in it 4 Terminate the individual wires to TB1 and TB2 as in Step 10 For your convenience TB1 and TB2 terminal blocks are removable 5 Route the cabling as needed to avoid any damage Additional wire ties and tie bases are provided to allow strain relief for the wire Figure 12 Installing the Remote Keypad Assembly into the Host Enclosure XRKMK Option For...

Отзывы: